期刊文献+

偏振敏感光学相干层析对鸡肉组织两种变质过程的表征 被引量:6

Characterization of Dehydration and Proteolysis Process of Chicken Muscle Using Polarization-Sensitive Optical Coherence Tomography
原文传递
导出
摘要 利用偏振敏感光学相干层析(PS-OCT)成像技术可以测量鸡肉新鲜度对鸡肉相位延迟的影响。给出了两种组织变质过程中PS-OCT的测量结果,通过组织双折射光学特性的数据提取反映了鸡肉脱水和水解两种不同过程。脱水过程主要影响组织的折射率和微纤维尺寸,双折射随鸡肉脱水程度增加而增大,过程由表及里,最后随深度均匀分布。水解过程主要影响组织中纤维状散射单元的比例和分布一致性,双折射随鸡肉水解状态而减弱,过程是由里及表,最终随水解完成而消失。实验结果显示了PS-OCT测量能够反映组织变质过程的结构和光学特性,并具有成为检测肉类新鲜度方法的潜力。 Two type degeneration processes: dehydration and proteolysis are studied, and the description based on polarization sensitive optical coherence tomograph (PS-OCT) measurement is presented respectively. Birefringent changes due to dehydration or proteolysis process are different. For the former case, the average birefringence increases with dehydration, caused by the size and index changes of muscle fibers. However, the hydrolysis process shows an opposite tendency. The average birefringence decreases with proteolysis, which can be explained by the damage of fibrous microstructures and the appearance of isotropic scattering elements. The above experimental results reveal different optical and microstructural changes in these two degeneration processes, and can be used to evaluate the muscle quality.
出处 《中国激光》 EI CAS CSCD 北大核心 2011年第12期96-101,共6页 Chinese Journal of Lasers
基金 国家自然科学基金(10974114)资助课题
关键词 生物光学 光学相干层析 双折射 偏振 biological optics optical coherence tomography birefrigence polarization
  • 相关文献

参考文献16

  • 1Michael R. Hee, David Huang, Eric A. Swanson et al.. Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging[J]. J. Opt. Soc. Am. B, 1992, 9(6): 903~908.
  • 2孟卓,姚晓天,姚晖,刘铁根,李燕妮,王冠华.光学相干层析用于检测早期人工龋齿[J].中国激光,2010,37(11):2709-2713. 被引量:17
  • 3L. Li, N. Zeng, L. F. Yang. Linear polarization detection of polarization-sensitive optical coherence tomography in the early detection of the application of dental caries[C]. SPIE, 2010, 7845: 78452O.
  • 4汪毅,陈晓冬,李海峰,李乔,郁道银.单探测器偏振相干层析的生物组织成像[J].中国激光,2009,36(10):2534-2537. 被引量:4
  • 5H. J. Swatland. Effect of pH on the birefringence of skeletal muscle fibers measured with a polarizing microscope[J]. Trans. Am. Mcrosc. Soc., 1990, 109(4): 361~367.
  • 6L. K. Srebnitskaya, G. N. Vishnyakov, S. A. Neimanl et al.. Reconstruction of the two-dimensional birefringence map of the skeletal muscle sarcomere in relaxed and rigor state by interference microscopy data[J]. Biophysics, 2001, 46(3): 494~499.
  • 7J. J. Pasquesi, S. C. Schlachter, M. D. Boppart et al.. In vivo detection of exercise-induced ultrastructural changes in genetically-altered murine skeletal muscle using polarization-sensitive optical coherence tomography[J]. Opt. Express, 2006, 14(4): 1547~1556.
  • 8A. D. Weaver, B. C. Bowker, D. E. Gerrard. Sarcomere length influences postmortem proteolysis of excised bovine semitendinosus muscle[J]. J. Anim. Sci., 2008, 86(8): 1925~1932.
  • 9代祥松,曾楠,何永红,马辉.频域偏振敏感光学相干层析系统的研制及应用研究[J].光电子.激光,2008,19(11):1502-1506. 被引量:5
  • 10J. F. de Boer, T. E. Milner. Review of polarization sensitive optical coherence tomography and Stokes vector determination[J]. J. Biomed. Opt., 2002, 7(3): 359~371.

二级参考文献79

共引文献42

同被引文献155

  • 1邵永红,何永红,马辉,王淑霞.检测工程聚合物材料新方法研究[J].激光与红外,2006,36(9):878-879. 被引量:3
  • 2蒋啸宇,曾楠,何永红,马辉.基于旋转偏振角的线偏振扫描成像方法研究[J].生物化学与生物物理进展,2007,34(6):659-663. 被引量:8
  • 3梁铨廷.物理光学[M].北京:机械工业出版社,1983.143-145.
  • 4M. R. Hee, D. Huang, E. A. Swansonetal.. Polarizatiowsensitive low coherence reflectometer for birefringence characterization and ranging[J]. J. Opt. Soc. Am. B, 1992, 9(6): 903"-908.
  • 5Shuliang Jiao, Wurong Yu, George Stoica e- al.. Optical fiber- based Muller optical coherence tomography [J].Opt. Lett. , 2003, 28(14): 1206-1208.
  • 6B. H. Park. Fiber-Based Polarization-Sensitive Optical Coherence Yomography[D]. Irvine: University of California, 2005. 56-110.
  • 7S. Makita, M. Yamanari, Y. Yasuno. Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging[J]. Opt. Express, 2010, 18(2) : 854-876.
  • 8T. Torzicky, M. Pircher, S. Zotter et al.. Automated measurement of choroidal thickness in the human eye by polarization sensitive optical coherence tomography [J ]. Opt. Express, 2012, 20(7) : 7564-7574.
  • 9B. Elmaanaoui, B. Wang, J. C. Dwelle et al.. Birefringence measurement of the retinal nerve fiber layer by swept source polarization sensitive optical coherence tomography [J ]. Opt. Express, 2011, 19(11) : 10252-10268.
  • 10C. Rashidifard, S. Martin, N. Kumar et al.. Assessment of rotator cuff tendon integrity with single detector polarization sensitive optical coherence tomography[C]. Lasers and Electro- Optics, 2011. ATuC2.