期刊文献+

重晶石混凝土医用加速器机房屏蔽防护效能分析 被引量:1

Shielding Protection Effectiveness Analysis of Medical Accelerator Room by Barite Concrete
下载PDF
导出
摘要 目的:分析检测重晶石混凝土配合比,结合加速器机房屏蔽防护要求,进行屏蔽防护效能的剂量估算。方法:基于15 MV加速器主要防护关注点,参考国家标准和NCRP 151#报告推荐方法,进行屏蔽防护设计和计算。结果:采用重晶石混凝土建设医用加速器机房,其施工工艺直接影响混凝土容重比和机房屏蔽防护效能。结论:重晶石混凝土建设机房可减小墙体厚度,能有效屏蔽X射线、电子线和中子污染。 Objective To analyze the barite concrete mixing ration and estimate the medical accelerator room's effectiveness according to its shielding protection requirements.Methods Based on important shielding concerns of the 15MV accelerator room,the design and calculation of shielding protection were performed,with national standards and NCRP 151# report turned to.Results When constructing medical accelerator room by barite concrete,the technique could affect mixing ration and shield protection effectiveness directly.Conclusion The medical accelerator room by barite concrete,with a reduced wall thickness,can shield X ray,electron and neutron pollution.
出处 《医疗卫生装备》 CAS 2011年第11期117-118,共2页 Chinese Medical Equipment Journal
关键词 医用加速器 重晶石混凝土 剂量估算 屏蔽防护 medical accelerator barite concrete dose estimation shielding protection
  • 相关文献

参考文献4

  • 1GB18871-2002.电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2002:177.
  • 2GBZ126-2002医用电子加速器卫生防护标准[S].北京:中国标准出版社,2002.
  • 3GBZ/T201.1-2007放射治疗机房辐射屏蔽规范第J部分:一般原则[S].北京:中国标准出版社.2007.
  • 4NCRP Report No.151 Structural Shielding Design and Evaluation for Megavoltage X- Ray and Gamma-Ray Radiotherapy Facilities [S]. Bethesda : NCRP, 2005.