期刊文献+

植入性心脏电器械的远程监测系统 被引量:3

下载PDF
导出
摘要 植入性心脏电器械(IECD)包括起搏器、埋藏式心脏转复除颤器、心脏再同步化治疗和植入性心脏事件记录仪,这些装置是智能化的器械,可以提供器械的程控参数和功能状态,并储存了大量的有诊断价值的资料。IECD的远程监测就是利用相应的设施获取或读取这些信息,发送至监测中心,进行诊断和处理。目前4家器械生产厂家都推出了各自的远程监护系统:①百多力的Home Monitoing;②波士顿科学的Latitude;③圣犹达的Merlin.netTM;④美敦力的CarelinkTM。4种远程监测系统通过有线和/或无线方式与IECD通讯,均能储存所有的腔内心电图,而实现远程监测、远程随访。但4种系统传送信息的方式以及监测的参数略有差异。
出处 《中国心脏起搏与心电生理杂志》 北大核心 2011年第6期478-481,共4页 Chinese Journal of Cardiac Pacing and Electrophysiology
  • 相关文献

参考文献16

  • 1Kleemann T, Becker T, Doenges K, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter defibrillators over a period of > 10 years [ J ]. Circulation, 2007,115 ( 19 ) : 2 474.
  • 2Neuzil P, Taborsky M, Holy F, et al. Early automatic remote detection of combined lead insulation defect and ICD damage [ J ]. Europace ,2008, 10( 5 ) :556.
  • 3Spencker S, Coban N, Koch L, et al. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-de-fibrillator patients due to lead failure [ J ]. Europace, 2009,11 ( 4 ) : 409.
  • 4Sweesy MW, Erickson SL, Crago JA, et al. Analysis of the effectiveness of in-office and transtelephonic follow-up in terms of pace- maker system complications[J]. Pacing Clin Electrophysiol,1994, 17(11 Pt 2) :2 001.
  • 5Lazarus A. Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database [ J ]. Pacing Clin Electrophysiol, 2007, 30( Suppl 1 )S2.
  • 6Nielsen J C, Kottkamp H, Zabel M, et al. Automatic home monitoring of implantable cardioverter defibrillators [J]. Europace, 2008, 10(6) : 729.
  • 7Ellery S, Pakrashi T, Paul V, et al. Predicting mortality and rehospitalization in heart failure patients with home monitoring-the HomeCARE pilot study [ J ]. Clin Res Cardiol, 2006,95 ( Suppl 3 ) Ⅲ29.
  • 8Perings C, Klein G, Toft E, et al. The RIONI study rationale and design: validation of the first stored electrograms transmitted via home monitoring in patients with implantable defibrillators [ J ]. Europace, 2006, 8(4) : 288.
  • 9Ritter O, Bauer WR. Use of " IEGM Online" in ICD patients-early detection of inappropriate classified ventricular tachycardia via home monitoring[J]. Clin Res Cardiol, 2006, 95(7) : 368.
  • 10Saxon LA, Boehmer JP, Neuman S, et al. Remote Active Monitoring in Patients with Heart Failure (RAPID-RF) : Design and rationale [ J ]. Journal of Cardiac Failure,2007,13 ( 4 ) : 241.

同被引文献34

  • 1臧红云,王冬梅,韩雅玲,杨桂棠,孙鸣宇.起搏器参数调整对患者生活质量的影响[J].中国临床康复,2004,8(18):3438-3439. 被引量:6
  • 2Varma N, Michalski J, Epstein AE,et al. Remote monitoring of im- plantable cardioverter-defibrillator lead and generator performance the Lumos-T safely reduces routine office device follow-up (TRUST) trial[ J]. Circ Arrhythm Electrophysiol,2010, 3 (5) :428.
  • 3Crossley GH, Boyle A, Vitense H, et al. CONNECT Investigators. The CONNECT ( Clinical evaluation of remote notification to reduce time to clinical decision) triM:the value of wireless remote monito-ring with automatic clinician alerts[ J]. J Am Coil CardioI,2011,57 (10) :1 181.
  • 4Saxon LA, Hayes DL, Gilliam FR, et al. Long-term outcome after ICD and CRT implantation and influence of remote device follow- up: the ALTITUDE survival study [ J ]. Circulation,2010,122 (23) : 2 359.
  • 5Tracy CM, Epstein AE, Darbar D, et al. 2012 ACCF/AHA/HRS focused update of the 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society[ J]. Circulation, 2012,126(14) :1 784.
  • 6Omera O, Bulava A. The benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators [ J ]. Neuro Endocrinol Lett ,2014,35 (Suppl 1 ) :40.
  • 7Varma N, Pavri BB, Stambler B, et al. Same-day discovery of im- plantable cardioverter defibrillator dysfunction in the TRUST remote monitoring trial: influence of contrasting messaging systems[ J] . Eu- ropace,2013,15 (5) :697.
  • 8Gu6don-Moreau L, Chevalier P, Marqui6 C, et al. Contributions of remote monitoring to the follow-up of implantable cardioverter - de- fibrillator leads under advisory[ J]. Eur Heart J, 2010, 31 (10) :2 246.
  • 9Gurdon-Moreau L, Lacroix D, Sadou! N, et al. A randomized study of remote foUow-up of implantab|e cardioverter defibrillators: safety and efficacy report of the ECOST trial[J]. Eur Heart J, 2013, 34 (8) :605.
  • 10Gudon-Moreau L, Kouakam C, Klug D ,et al. Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: a Sub- study of the ECOST Trial[ J]. J Cardiovasc Electrophysiol,2014,25 (7) :763.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部