期刊文献+

囊袋内植入不同襻长人工晶体后偏心的研究 被引量:5

Measurement of posterior chamber intraocular lens decentration after intraocular implantation
下载PDF
导出
摘要 目的: 测量不同襻长的后房型人工晶体囊袋内植入术后偏心值,确定超声乳化白内障摘除更适合囊袋内植入的人工晶体的襻长。方法:采用通过眼底照相系统摄取人工晶体植入术后1 周和3 个月前囊像,应用自制同心圆图表确定角膜和人工晶体光学中心,利用计算机软件测量两点之间的直线距离作为人工晶体偏心值,对62 只襻长分别为12.0mm 和12.5mm 的后房型人工晶体眼行活体测量。结果:襻长12.0mm 和12.5mm 人工晶体术后1 周和3 个月的偏心值分别为0 .25 ±0.15mm 、0.03 ±0 .13mm 和0.20 ±0.07mm 、0.21 ±0 .10mm .结论:总长度为12 .5mm 的人工晶体囊袋内植入比12.0mm 的更稳定。 Objective:To determine the appropriate overall length of an IOL for phacoemulsification and intracapsular implantation.Methods:We studied 62 eyes that had undergone phacoemulsification and intracapsular lens implantation with lenses of different overall lengths.Pictures of the anterior capsular section were taken in situ illumination 1 week and 3 months postoperatively.The center point of the cornea and crystalline lens were located with a circle topography and the distance between them was measured online by computer.Results:The mean decentration of 12.0 and 12.5mm IOL was 0.30 (plus/minus) 0.13 and 0.12 (plus/minus) 0.10mm at 1 week and 3 months postoperatively.Conclusion:The 12.5mm IOL was more stable than the 12.0mm IOL after intracapsular implantation.
出处 《眼视光学杂志》 1999年第4期222-223,共2页 Chinese Journal of Optometry & Ophthalmology
关键词 偏心 超声乳化术 白内障 人工晶体植入术 Lenses, intraocular Decentration Phaco
  • 相关文献

参考文献3

二级参考文献4

共引文献118

同被引文献39

  • 1王铮,杨斌,黄肖虹,黄国富,邱平,陈家祺.散瞳前后瞳孔中心偏移对波前引导准分子激光原位角膜磨镶术手术的影响[J].中华眼科杂志,2005,4(1):24-26. 被引量:11
  • 2罗汉暄.缩瞳前后瞳孔中心偏移对有晶状体眼前房人工晶状体定位的影响[J].国际眼科杂志,2006,6(5):1064-1065. 被引量:1
  • 3Eppig T,Scholz K,Loffler A,et al.Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in amodel eye.J Cataract Refract Surg,2009,35:1091-1100.
  • 4Taketani F,Matuura T,Yukawa E,et al.Influence of intraocular lens tilt and decentration on wavefront aberrations.J Cataract Refract Surg,2004,30:2158-2162.
  • 5De Castro A,Rosales P,Marcos S.Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging Validation study.Cataract Refract Surg,2007,33:418-429.
  • 6Mester U,Sauer T,Kaymak H.Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes.J Cataract Refract Surg,2009,35:485-490.
  • 7Gonvers M,Sickenberg M,van Melle G.Change in capsulorhexis size after implantation of three types of intraocular lenses.J Cataract Refract Surg,1997,23:231-238.
  • 8Lee DH,Shin SC,Joo CK.Effect of a capsular tension ring on intraocular lens decentration and tilting after cataract surgery.J Cataract Refract Surg,2002,28:843-846.
  • 9Hara T,Hara T,Kojima M,et al.Specular microscopy of the anterior lens capsule after endocapsular lens implantation.J Cataract Refract Surg,1988,14:533-540.
  • 10Hayashi H,Hayashi K,Nakao F,et al.Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome.Br J Ophthalmol,1998,82:1429-1432.

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部