摘要 研究污秽潮湿状态下绝缘子表面电场特征对提高绝缘子可靠性有重要的意义。基于污秽潮湿状态绝缘子周围电场的电阻性特点,采用离散电阻模型研究了轴向不均匀的污层对绝缘子电场和电位分布的影响。计算结果表明:绝缘子表面电场强度切向分量与绝缘子表面污秽轴向分布不均匀程度有关;流过污层的泄漏电流的焦耳热效应会加剧绝缘子表面电导率的不均匀程度。 It is meaningful for the improvement of insulator reliability to research the surface electric field characteristics in a condition of dirt and moisture.Based on the resistance characterisc of the insulator field in the condition,this paper adopts the discrete resistor model to study the influence of nonuniform pollution layer along the insulator’s axis on the distributions of insulator’s electric field and potential.The results show that the tangential component of the insulator’s surface electric field intensty depends on the nonuniform,and the nonuniform of insulator’s surface conductivity becomes worse by Joule heat effect of the leakage current through pollution layer.
出处 《南方电网技术》 2011年第5期72-76,共5页 Southern Power System Technology
关键词 绝缘子 离散电阻模型 表面电导率 污闪 insulator discrete resistor model surface conductivity pollution flashover
  • 相关文献

参考文献7

  • 1张重远,黄彬,王娟,律方成.悬式瓷制绝缘子泄漏电流与表面污秽的关系[J].高电压技术,2008,34(4):655-659. 被引量:20
  • 2关志成,毛颖科,王黎明.污秽绝缘子泄漏电流特性研究[J].高电压技术,2008,34(1):1-6. 被引量:75
  • 3关志成,崔国顺,董颖.局部表面电导率法及其应用[J].电瓷避雷器,1994(2):20-25. 被引量:17
  • 4LOOMS J S T.Insulators for High Voltages. . 1988
  • 5SIMA W,,YUAN T,YANG Q,et al.Effect Of Non-Uniform Pollu-tion On The Withstand Characteristics Of Extra High Voltage(EHV)Suspension Ceramic Insulator String. IET Generation Transmis-sion&Distribution . 2010
  • 6Gubanski S M,Wankowicz G J.Distribution of natural pollution surface layers on silicone rubber insulators and their UV absorption. IEEE Transactions on Electron Insulation . 1989
  • 7XU G,MCGRATH P B.Electrical and Thermal Analysis of Polymer Insulator under Contaminated Surface Conditions. IEEE Transac-tions on Electrical Insulation . 1996

二级参考文献27

  • 1关志成,张仁豫,薛家麒,马霜,李楠.自然污秽可溶盐构成及其对污闪电压值的影响[J].电瓷避雷器,1989(6):13-18. 被引量:44
  • 2贺博,林辉.人工污秽试验中绝缘子泄漏电流的统计特性[J].高电压技术,2006,32(8):4-6. 被引量:15
  • 3张仁豫,关志成,薛家麒,马霜.局部表面电导率——表征绝缘子污秽程度的一种新方法[J].高电压技术,1990,16(1):20-26. 被引量:19
  • 4朱康,曹永兴,曾宏.110kV电压等级人工污秽试验室建设[J].四川电力技术,1997,20(2):12-13. 被引量:1
  • 5GB/T 4585-2004.交流系统用高压绝缘子的人工污秽试验[S].2004.
  • 6Mao Yingke, Guan Zhicheng, Wang Liming, et al. Investigation of leakage current of outdoor insulators with a newly developed monitoring system[C]. Proceedings of the 14th International Symposium on High Voltage Engineering. Beijing, China, 2005: 26-29.
  • 7Mao Yingke, Guan Zhicheng, Wang Liming, et al. Development of a multi channel leakage current monitoring system for the outdoor insulators[C]. International Conference on Condition Monitoring and Diagnosis. Changwon, Korea, 2006: 2-5.
  • 8关志成,张仁豫,朱德恒.染污绝缘子临闪时泄漏电流和闪络电压之间关系的研究[R].北京:清华大学,1981:11-19.
  • 9张仁豫 朱德恒 关志成.自然染污与人工染污绝缘子的闪络电压与泄漏电流间关系的研究.电工技术学报,1984,2(12):1-5.
  • 10Guan Zhicheng, Zhang Renyu. A study of parameters to express the pollution severity of insulators[C]. Proceedings of ICPST Session RA. Beijing, China, 1991.

共引文献101

同被引文献58

引证文献5

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部