针对在繁忙干线电气化区段实行接触网"V"形天窗停电作业发生的触电伤害进行了整体分析,并提出了一些相应的意见和建议,为牵引供电系统的安全运行和维护提供借鉴。
The integral analysis has been made on the shock injury caused by the V-stop window time power off operation for the overhead contact system in electrified section of a busy trunk line,and puts forward relative suggestions and proposals,providing references for safety operation and maintenance for the traction power supply system.