期刊文献+

胶囊内窥镜的无线能量传输系统优化设计 被引量:11

Optimal design of wireless power transmission system for capsule endoscopes
下载PDF
导出
摘要 随着无线胶囊内窥镜的发展,无线能量传输技术越来越受到人们的关注。无线能量传输技术在应用过程受到尺寸、安全性等诸多因素的约束,如何在这些约束条件下设计安全、高效的无线能量传输系统是目前研究的重点。提出了磁场均匀度、频率稳定度、三维线圈姿态稳定度和接收能量均匀度等指标来综合评价能量传输系统性能,设计并实现了测试平台来测量这些性能指标,为进一步对整个系统进行优化设计提供依据。采用上述方法对一套为胶囊内窥镜设计的无线能量传输系统进行了测量与评价,结果表明系统可在体积为Φ12 mm×14 mm的空间内提供不低于450 mW的能量,且满足稳定性和安全性要求,实验证明了该方法的可行性。 With the development of the wireless capsule endoscopes,the technology of wireless power transmission attracts more and more attention.However,its application is limited by the factors,such as size and safety.Under these restraints,the design of wireless power transmission system with safety and high efficiency is a hot tissue recently.Indexes,for example,magnetic field uniformity,frequency stability,the orientation stability of 3-demension receiving coil and the uniformity of receiving power,were presented to evaluate the transmission system.The measuring table was designed and realized to measure these indexes,and this could provide the reasons for further optimization of the system.A wireless power transmission system for capsule endoscopy was measured and estimated in this method.The results show that the wireless power transmission system can deliver at least 450mW energy in a volume of Φ12mm×14mm,and satisfies the demand of the receiving stability and safety.The experiments verified the validity.
出处 《电子测量与仪器学报》 CSCD 2011年第12期1060-1065,共6页 Journal of Electronic Measurement and Instrumentation
基金 国家863计划(2007AA04Z234 2008AA04Z201) 国家自然科学基金(60875061 31170968 30800235) 载人航天领域预先研究(010203) 上海市科委(09DZ1907400)资助项目
关键词 无线能量传输系统 优化平台 磁场均匀度 频率稳定度 姿态稳定度 接收能量稳定度 wireless power transmission system platform for optimization magnetic field uniformity frequency stability safety of human tissue receiving power uniformity
  • 相关文献

参考文献4

二级参考文献38

共引文献31

同被引文献76

  • 1姜萍萍,付文浩,王志武,颜国正.用于胃肠道微型机器人的组合螺线管式无线能量发射系统研究[J].仪器仪表学报,2021,42(2):114-122. 被引量:8
  • 2邝帅,颜国正,王志武,姜萍萍,韩玎.无线胶囊内窥镜新型接收线圈结构设计与分析方法[J].仪器仪表学报,2019,40(11):55-63. 被引量:16
  • 3MA Guan-ying YAN Guo-zheng HE Xiu.Study on Wireless Power Transmission for Gastrointestinal Microsystems Based on Inductive Coupling[J].Chinese Journal of Biomedical Engineering(English Edition),2007,16(2):71-78. 被引量:8
  • 4CEPOLINA F, MICHELINI R C. Review of robotic fixtures for minimally invasive surgery [ J ]. The Interna- tional Journal of Medical Robotics and Computer Assis- ted Surgery, 2004, 1 ( 1 ) : 43-63.
  • 5JAYENDER J, PATEL R V, NIKUMB S. Robot-as- sisted active catheter insertion: algorithms and experi- ments [ J ]. International Journal of Robotics Re- search, 2009, 28(9) : 1101-1117.
  • 6FU Y L, LIU H, HUANG W T, Steerable catheters in minimally invasive vascular surgery [ J ]. The Interna- tional Journal of Medical Robotics and Computer Assis- ted Surgery, 2009, 5(4) : 381-391.
  • 7LIU H, FU Y L, YAN Z Y. A dynamic model for the active catheter actuated by the shape memory alloy coil spring [ C ]. 2009 IEEE International Conference on Mechatronics and Automation, 2009: 1968-1973.
  • 8IKUTA K, MATSUDA Y, YAJIMA D, et al. Pressure pulse driven method for precise bending control of hydraulic active catheter [ C ]. Proceedings of the IEEE RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2010: 94-99.
  • 9IKUTA K, MATSUDA Y, YAJIMA D, et al. Precise bending angle control of hydraulic active catheter by pressure pulse drive [ C ]. IEEE International Conference on Robotics and Automation ICRA, 2010: 5588-5593.
  • 10FU Y L, LI X L, WANG S G, et al. Research on the axis shape of an active catheter [ J ]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2008, 4(1): 69-76.

引证文献11

二级引证文献115

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;