期刊文献+

现浇混凝土空心楼盖体系受弯研究 被引量:1

Flexionmoment of hollow and girderless concrete floor
下载PDF
导出
摘要 现浇混凝土空心无梁楼盖有两个突出的特点:一是在板内预埋有高强薄壁管,从而形成空心,减轻结构自重;二是在框架柱之间设有暗扁梁,以增强结构整体刚度,提高结构整体抗震性能。本文以现浇混凝土空心无梁楼盖两个突出的特点为基础,对其基本力学性能进行研究分析,探讨合理的计算方法。 Hollow and girderless floor has two dramatic features.One is that the high tensile thin steel pipes are buried in plank,thus forming hollowness,which alleviates the dead-weight.The other is that the shaded oblate beam is set up between pipes of post,which strengthens whole structure stiffness and increase earthquake-resistant function.The paper analyzes its mechanical property and discusses the reasonable calculation method.
出处 《河北工业科技》 CAS 2012年第1期44-48,61,共6页 Hebei Journal of Industrial Science and Technology
关键词 空心无梁楼盖 暗扁梁 薄壁钢管 混凝土 弯矩 hollow and girderless floor shaded oblate beam thin steel pipes concrete flexural moment
  • 相关文献

参考文献5

  • 1高连玉.混凝土行业技术创新与产业化[J].房材与应用,2002,30(3):5-9. 被引量:1
  • 2DURRANI A J, DU Y, LUO Y H. Seismic resistance of no ductile slab-column connection in existing fiat-column build- ings[J]. ACI Structural Journal,1995,92(5) :101-108.
  • 3MEGALLY S,GHALI A. Design considerations for slab-col- umn connection in seismic zone[J]. ACI Structural Journal, 1994,91 (3):132-137.
  • 4GBJ130-1990,钢筋混凝土升板结构技术规范[S].
  • 5傅学怡.宽扁梁设计建议[J].建筑结构,1999,29(2):11-14. 被引量:34

二级参考文献2

  • 1傅学怡 龚非吉 等.宽扁梁在深圳文华高层商住楼中的应用研究.第三届高层建筑抗震技术交流会论文集[M].扬州,1991,11..
  • 2傅学怡,第三届高层建筑抗震技术交流会论文集,1991年,11页

共引文献35

同被引文献6

  • 1赵鸿铁.钢与混凝土组合结构[M].北京:科学出版社,2000.
  • 2[美]亚历山大·纽曼.金属建筑系统设计与规范[M].余洲亮,译.北京:清华大学出版社,2001.
  • 3邱则有.现浇混凝土空腔楼盖[M].北京:中国建筑工业出版社,2007.
  • 4全学友,王巍.现浇圆形管空腔楼盖中单向模型板受力性能的试验研究[G]//全国现浇混凝土空腔楼盖结构技术交流会论文集,2005.
  • 5杨建军,王本淼,杨承想,等.钢一混凝土组合空腔楼盖的研发[G]//中国钢协结构稳定与疲劳分会第12届(ASSF-2010)学术交流会暨教学研讨会论文集,2010:120-124.
  • 6杨想红.钢-混凝土组合空腹板架结构与组合结构对比研究[J].建筑知识,2012,32(7):131-131. 被引量:2