摘要 The ionic wind has good application prospects in the fields of air flow control and heat transfer enhancement. The key for successful applications is how to improve the velocity and how to increase the active area of the ionic wind. This paper designed a needle array-mesh type electrohydrodynamic (EHD) gas pump. The use of needle array electrode where corona discharge started simultaneously could enlarge the active area. The velocity of the ionic wind could increase by placing several single-stage ionic wind generators in series appropriately, called as serial staged generator. The maximum average flow velocity of 16.1 m/s and volumetric flow of 303.5 L/min were achieved at the outlet of a 25-stage gas pump and the conversion efficiency was approximately 2.2%. The ionic wind has good application prospects in the fields of air flow control and heat transfer enhancement. The key for successful applications is how to improve the velocity and how to increase the active area of the ionic wind. This paper designed a needle array-mesh type electrohydrodynamic (EHD) gas pump. The use of needle array electrode where corona discharge started simultaneously could enlarge the active area. The velocity of the ionic wind could increase by placing several single-stage ionic wind generators in series appropriately, called as serial staged generator. The maximum average flow velocity of 16.1 m/s and volumetric flow of 303.5 L/min were achieved at the outlet of a 25-stage gas pump and the conversion efficiency was approximately 2.2%.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第6期693-697,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(No.50577053)
关键词 electrohydrodynamic (EHD) corona discharge ionic wind gas pump electrohydrodynamic (EHD) corona discharge ionic wind gas pump
  • 相关文献

参考文献15

  • 1Robinson M. 1961, AIEE Trans., 80:143.
  • 2Yue Yonggang, Hou Junping, Ai Zhongliang, et al. 2006, Plasma Sci. Technol., 8:697.
  • 3Richard M. 2005, J. Electrostat., 63:711.
  • 4Yuan Junxiang, Qiu Wei, Zheng Cheng, et al. 2009, Proceedings of the CSEE, 29:110 (in Chinese).
  • 5Roth J R. 2003, Phys. Plasmas, I0:2117.
  • 6Sidorenko A A. 2008, Flight testing of DBD plasma separation control system. Presented at 46th AIAA Aerospace Sciences Meeting and Exhibit, Reno, Nevada. American Institute of Aeronautics and As- tronautics, Reston, USA.
  • 7Moreau E. 2007, J. Appl. Phys., 40:605.
  • 8Huang Ren-Tsung. 2009, Energy Convers. Manage., 50:1789.
  • 9Jewell-Larsen N E, Ran H, Zhang Y, et al. 2009, Elec- trohydrodynamie (EHD) Cooled Laptop. Presented at 25th IEEE SEMI-THERM Symposium, San Jose, Cal- ifornia. IEEE, New York, USA.