期刊文献+

减小塔影效应载荷波动的独立变桨距控制研究 被引量:5

The Study of Individual Pitch Control on Reducing the Load Fluctuation of Tower Shadow
下载PDF
导出
摘要 针对塔影效应引起风电机组载荷波动的情况进行研究,对其引入独立变桨距控制。建立风电机组风轮的线性时变模型,并将其写成状态方程的形式,进而引入Coleman变换将其变换成线性时不变模型。然后,在此模型基础上,加入PID控制器,从而完成独立变桨距控制系统的设计。在塔影效应的影响下,分别对独立变桨距控制和统一变桨距控制情况下风电机组的载荷波动进行仿真对比研究,并利用雨流统计法对风电机组进行疲劳分析。研究结果表明:在塔影效应影响下,采用独立变桨距控制策略的风电机组载荷波动较采用统一变桨距控制策略的风机有明显改善,削弱了塔影效应载荷波动的影响,并延长了机组的使用寿命。 Load fluctuation conditions of wind turbine under tower shadow was researched and individual pitch control was introduced.Establish the linear time-varying model of the rotor and make it into the form of the state equation.Then,make it into the linear time invariant model through Coleman transformation.Based on this model,achieve the design of individual pitch system with PID controller.load fluctuation conditions of wind turbine were simulated and compared under tower shadow between individual pitch control and collective pitch control and analyse the fatigue damage of wind turbine through rainflow cycle counting.The result shows that load fluctuation of wind turbine using the individual pitch control under tower shadow has better effect and it weakens the load fluctuation effect of tower shadow,extends the working life of wind turbine.
出处 《电气技术》 2012年第1期6-10,共5页 Electrical Engineering
基金 国家十一五支撑计划(2006BAA01A03) 大型风力发电机组工厂试验平台建设(1091250-1-00)
关键词 独立变桨距 统一变桨距 Coleman变换 塔影效应 载荷波动 PID控制器 俯仰弯矩 偏航弯矩 individual pitch collective pitch Coleman transformation tower shadow load fluctuation PID controller tilt moment yaw moment
  • 相关文献

参考文献6

二级参考文献36

  • 1林勇刚,李伟,叶杭冶,邱敏秀,金波,刘湘琪.变速恒频风力机组变桨距控制系统[J].农业机械学报,2004,35(4):110-114. 被引量:43
  • 2林勇刚,徐立,李伟,陈晓波.电液比例变桨距风力机半物理仿真试验台[J].中国机械工程,2005,16(8):667-670. 被引量:26
  • 3林勇刚,李伟,陈晓波,顾海港,叶杭冶.大型风力发电机组独立桨叶控制系统[J].太阳能学报,2005,26(6):780-786. 被引量:62
  • 4Thomas Ackermann, Lennart soder. Wind energy technology and current status: a review [J]. Renewable and Sustainable Energy Reviews, 2000 (4) : 315 -374.
  • 5Naruhito Kodama, Tomoyuki Matsuzaka, Sayosi Yamada. Modeling analysis of the NEDO 500-kW wind generator [J]. ELetrieal Engieering in Japan, 2001 (3): 37 - 47.
  • 6Jelavic M, Petrovic V, Peric N. Individual pitch control of wind turbine based on loads estimation [ C ]//34th Annual Conference of IEEE-IECON. Orlando, 2008: 228 - 234.
  • 7Shigeo M, Hideaki N, Masayuki S. Sensorless output maximization control for variable-speed wind genera- tion system using IPMSG [ J ].IEEE Transactions on Industry Applications ,2005,41 ( 1 ) :60 -67.
  • 8H.Armaris,C.Vilar,et al.,Frequency domain analysis of flicker produced by wind energy conversions systems,Paper accepted for presentation at the 8《'th》 international conference on harmonics and quality of power ICHQP' 98,jointly organized by IEEE/PES and NTUA,Athens,Greece,October 14 -16,1998.
  • 9Carolina Vilar Moreno,Hortensia Amaris Duarte,Julio Usaola Carcia,Propagation of flicker in electric power networks due to wind energy conversions systems,IEEE Transactions on energy conversion,Vol.17,No.2,June 2002.
  • 10Torbjorn Thiringer,Jau-Ake,Dahlberg,Periodic power pulsalions from a three-bladed wind turbine,www.elkraft,chalmers.se/Publikationer/EMKE,publ/Abstracts/Alsvik,pdf.

共引文献120

同被引文献53

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;