摘要
研究目的:七氟丙烷自动灭火系统灭火效率高、可靠性强,对保护的防护区内物品没有损坏,在对珍贵物品、机房、档案的保护方面越来越受到重视,但其各系统的施工难度大,周期长、技术要求高,研究切实可行的安装工艺,对施工整体顺利进行和项目验收使用很有必要。研究结论:对某办公楼七氟丙烷自动灭火系统的管道、设备、自动报警系统的安装工艺及系统联动调试反复研究以及后期跟踪回访,总结出了钢瓶间是整个系统的核心,钢瓶间设备的布置和安装需考虑预留操作空间和调试检修通道;消防主机、联动柜、多功能综合控制台等交流主电源,由消防控制室专用UPS双路电源箱直接引入。
Research purposes: The Heptafluoropropane automatic fire extinguishing system has been widely used for protection of the treasure goods, machine room and files room because of its high efficiency, reliability and no harm to the protected goods. But the construction of system is difficult, and the construction period is long with the high technical requirement. Therefore, it is very necessary to do research on its practical installation process for the purpose of ensuring the smooth construction progress and project acceptance. Research conclusions:From the research and review of the installation processes of the pipe, device and alarm system and the system linkage test of a heptafluoropropane automatic fire extinguishing system for one office building, it is concluded the steel cylinder room is the core of the system. When installing and arranging the devices in the steel cylinder room, the operation space and the passage for test and maintenance should be reserved. The main a. c power to the main fire host, linkage cabinet and multi -functional console should be fed from the special UPS dual power supply in the fire control room.
出处
《铁道工程学报》
EI
北大核心
2012年第1期78-82,共5页
Journal of Railway Engineering Society
关键词
七氟丙烷
气体灭火系统
安装工艺
施工要点
heptafluoropropane
gas fire extinguishing system
installation process
key points of construction