期刊文献+

生物可吸收材料在踝足骨折治疗中的应用 被引量:11

Clinical evaluation of absorbable implants in treatment of ankle and foot fractures
下载PDF
导出
摘要 目的评价生物可吸收材料在踝足骨折内固定治疗中的作用。方法 2006年6月~2010年6月,76例踝足骨折采用切开复位可吸收材料进行内固定。其中男49例,女27例;年龄18~62岁,平均46.6岁。骨折部位:踝关节骨折25例;跟骨骨折6例,跖趾骨骨折45例。结果随访10~48个月,平均22个月,骨折全部临床愈合;AOFAS功能评估优良率96%,并发症发生率4%均为异物反应。结论生物可吸收材料是治疗踝足部骨折的有效方法,正确选择适应症和手术操作是治疗成功的重要因素。 Objective To evaluate the effects of absorbable implants in treatment of ankle and foot fractures.Methods A total of 76 cases with ankle and foot fracture were operated with absorbable implants from Jun 2006 to Jun 2010.There were 49 males and 27 females,with average age of 46.6 year(s 18 to 62 years).There were 25 ankle frctures,6 calcaneal and 45 metatarsal and phalange fractures.Results All cases were followed up for 10 to 48 months(average 22 months).All fractures healed.The rate of excellent and good clinical results according to AOFAS system was 96%.The incidence of complications was 4% all were foreign-body reactions.Conclusion The absorbable implant was suitable for ankle and foot fractures.Appropriate indication and operative procedure were important for the successful treatment.
出处 《生物骨科材料与临床研究》 CAS 2012年第1期45-47,共3页 Orthopaedic Biomechanics Materials and Clinical Study
基金 浦东新区社发局科研项目(PW2010b-7)
关键词 可吸收性材料 踝足 骨折 内固定 Absorbable implants Ankle and foot Fracture Internal fixation
  • 相关文献

参考文献6

  • 1Mukherjee DP, Pietrzak WS. Bioabsorbable fixation: scientific, technical, and clinical concepts.J. Craniofac Surg, 2011, 22 ( 2 ) : 679-689.
  • 2Kitaoka HB, Alexander I J, Adelaar RS, et al. Clinical rating sys- tems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int, 1994, 15( 7 ): 349-353.
  • 3胡晓亮,丁菊红,秦惠敏,沈燕国,陆美群,张爱敏,胡牧.生物可吸收材料在短管状骨骨折髓内固定的临床应用[J].生物骨科材料与临床研究,2008,5(5):17-19. 被引量:11
  • 4Emond CE, Woelber EB, Kurd SK, et al. A comparison of the re- sults of anterior cruciate ligament reconstruction using bioabsorb- able versus metal interference screws: a recta-analysis, J Bone Joint Surg Am, 2011, 93( 6 ): 572-580.
  • 5Shikinami Y, Okuno M. Bioresorbable devices made of forged composites of hydroxyapatite ( HA ) particles and poly-L-lactide ( PLLA ). Part I. Basic characteristics. Biomaterials, 1999,( 20 ). 859-877.
  • 6Bostman OM, Pihlajamaki HK. Adverse tissue reactions to bioa- bsorbable fixation devices. Clin Orthop Relat Res, 2000,( 371 ) : 216-227.

二级参考文献9

共引文献10

同被引文献114

引证文献11

二级引证文献117

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部