期刊文献+

大连国际会议中心楼盖振动测试与分析 被引量:2

Test and analysis on floor vibration of Dalian International Conference Center
原文传递
导出
摘要 大连国际会议中心15.30m标高平台周圈均为大悬挑结构形式,各会议厅也主要采用大跨度钢楼盖,对人行激励可能会非常敏感。而该建筑功能对舒适度的要求较高,所以需重视人行激励下的楼盖振动问题。本工程中较多地采用悬挑与大跨度的结构形式,所以楼盖的竖向振动就成为比较重要的问题。对结构自振特性做了初算,并进行了现场测试,根据现场测试结果调校模型,将加速度分析结果与实测结果进行比对。列出了各分区的自振特性,根据各分区的功能情况进行加速度分析,并将达沃斯会议厅随机振动分析的加速度情况和国际标准组织ISO的方法进行了比较。 The 15.30m-platforms of Dalian International Conference Center are large cantilevered structures,and the meeting rooms are mainly large-span steel floors,which are sensitive to human excitation.Due to the high comfort performance requirement of the building,the floor vibration problem is important.In this project,long-cantilever and long-span structures are adopted much more,so the vertical vibration of the floor is an important problem.The structural vibration characteristics were analyzed and the field test was done.Based on the test values,the model was adjusted and the acceleration results of analysis were compared with the test values.The vibration characteristic of every part was introduced,the acceleration analyses of the parts were done,and the random vibration results of the DCC was compared with the method proposed by ISO.
出处 《建筑结构》 CSCD 北大核心 2012年第2期58-65,共8页 Building Structure
关键词 楼盖振动 舒适度 自振特性 峰值加速度 floor vibration comfort vibration characteristic peak acceleration
  • 相关文献

参考文献4

  • 1朱鸣,张志强,柯长华,张徐,李爱群.大跨度钢结构楼盖竖向振动舒适度的研究[J].建筑结构,2008,38(1):72-76. 被引量:83
  • 2American National Standard: Steel design guide series 11--Floor vibrations due to human activity [ S ]. American Institute of Steel Construction, 1997.
  • 3British Standard 6472: Guide to the evaluation of human exposure to vibration in building [ S ]. British Standard Institute, 1984.
  • 4大连理工大学工程力学系工业装备结构分析国家重点实验室,大连市建筑设计研究院有限公司.大连国际会议中心楼盖振动及减振方案[R].2011.

二级参考文献5

  • 1American Institute of Steel Construction, Canadian Institute of Steel Construction. Floor Vibrations Due to Human Activity (Steel Design Guide Series 11 )[S]. 1997.
  • 2Applied Technology Council. Minimizing Floor Vibration (ATC Design Guide 1 )[S]. 1999.
  • 3日本建築學會.建築物の振動に開する居住性能評價指針[S].2004.
  • 4Evaluation of human exposure to whole-body vibration[S]. International Standard, ISO 2631-2,1959.
  • 5MIDAS/SDSV2.4.0帮助手册.北京迈达斯技术有限公司,2001.