期刊文献+

JPEG2000压缩技术对乳腺微钙化灶诊断性能影响的研究 被引量:1

Effects of JPEG 2000 Compression Techniques on Diagnostic Accuracies of Breast Microcalcification
下载PDF
导出
摘要 目的:探讨采用JPEG 2000有损压缩技术压缩乳腺X摄影影像对乳腺簇状微钙化灶诊断性能的影响。方法:选择25例乳腺簇状微钙化灶X线摄影影像及30例正常对照病例影像,采用JPEG 2000压缩算法分别对其进行无损压缩及有损压缩,由2名放射科医生分两次进行阅片,并对是否发现乳腺簇状微钙化灶进行评价。采用受试者操作特性曲线对阅片结果进行分析。结果:2名放射科医生对采用2种不同压缩算法处理后的影像阅片结果相似,两者之间没有显著性差异。结论:采用有损压缩算法也能够满足乳腺簇状微钙化灶病例的阅片需求。 Objective To compare the diagnostic performance of breast microcalfication between the images with lossless and lossy techniques of JPEG 2000. Mothods Fifty-five cases (25 with single cluster of microcalcification, 30 controls) were selected by one radiologist not participating in the image reviewing. With the JPEG 2000 wavelet-based image compression algorithm, all images were compressed to 2 levels: lossless and lossy 20:1. Two radiologists evaluated the delectability of clustered microcalcification with two kinds of compressed images. The results were analyzed and compared by using the method of receiver operating characteristic(ROC) curves. Results ROC analysis results showed no significant difference in observer performance between the lossless and lossy compressed images. Conclusion The performance of lossy compressed images is equal to that of lossless compressed images in the interpreting the breast images with microcalcifications.
出处 《医疗卫生装备》 CAS 2012年第1期67-68,共2页 Chinese Medical Equipment Journal
关键词 乳腺癌 微钙化灶 JPEG2000 图像压缩 breast cancer microcalcification JPEG 2000 image compression
  • 相关文献

参考文献7

  • 1赵玉年,徐向红,崔怀萍,顾慷.全数字化乳腺X线立体定位及活检技术对早期乳腺癌诊断及治疗的价值[J].临床放射学杂志,2011,30(2):189-192. 被引量:17
  • 2朱少萍,张妙芳,麦耀文.全数字化乳腺X线摄影与传统乳腺X线摄影对比分析[J].放射学实践,2007,22(10):1110-1112. 被引量:5
  • 3Rong X J,Shaw C C,Johnston D A,et all. Microcalcification de- tectability for four mammographic detectors: flat-panel, CCD, CR, and screen/film[J]. Med Phys, 2002,29 (9) : 2 052- 061.
  • 4Del Turco M R,Mantellini P,Ciatto S,et ol. Full-field digital ver- sus screen-film mammography: comparative accuracy in concurrent screening cohorts[J]. Am J Roentgenol, 2007,189 (4) : 860-866.
  • 5Rothenberg B M ,Ziegler K M ,Aronson N. Technology evaluation center assessment synopsis: full-field digital mammography[J]. J Am Coil Radial, 2006,3 (8) : 586-588.
  • 6Penedo M ,Souto M ,Tahoces P G,et al. Free-response receiver op- erating characteristic evaluation of lossy JPEG2000 and object- based set partitioning in hierarchical trees compression of digitized mammograms[J]. Radiology, 2005,237 (2) :450-457.
  • 7Suryanarayanan S,Karellas A,Vedantham S,et al. A perceptual e- valuation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics[J]. J Digit Imaging, 2004,17 ( 1 ) : 64- 70.

二级参考文献14

  • 1葛玲玉,黄强,钱秉坤,许顺良,林冰影,刘小蕉,肖文波,陈燕琼,彭志毅.立体定位穿刺活检术对乳腺微小病变定性诊断的探讨[J].实用放射学杂志,2006,22(4):457-459. 被引量:5
  • 2柳光宇,陈灿铭,胡震,凌泓,沈坤炜,沈镇宙,邵志敏.乳腺X线立体定位活检方法的评价及选择[J].中华外科杂志,2006,44(19):1322-1324. 被引量:25
  • 3Fajardo LL, Pisano D J, Caudry DJ, et al. Stereotactic and sonograpbic large-core biopsy of nonpalpable breast lesions: results of the radiologic diagnostic ontology group V study. Acad Radiol,2004,11:293.
  • 4Donegan WL,Spratt JS. Cancer of the Breast. Phila 2 delphia:Saunders ,2002,477.
  • 5Helbich TH. Loecalization amt biopsy of breast lesion by magetie, resonance imaging guidance. J Magn Re, son Imaging,2001, 13:903.
  • 6Haffty BG, Lee C, Philpotts L,et al. Prognostic significance of mammographic detection in a eohort of conservatively treated breast cancer patients. Cancer J Sci Am, 1998,4:35.
  • 7Leung J, Meyer JE, Kaelin CM,et al. Surgical breast alter wire localization :improve in positive prediclive value 7 year after implementation of large core needle breast biopsy, Radiology,2001,176:42.
  • 8Skaane P,Young K,Skaaennald A.Comparison of Screen-film Mammography (SFM) and Full-field Digital Mammography (FFDM) with Soft-copy Reading in a Population-based Screening Program:The Oslo Ⅱ -Study[J].Radiology,2002,225 (9):267-268.
  • 9Schonhofen H,Arnold W,Hess T,et al.Digital Mammography:Experiences in its Clinical Application[J].Fortschr Rontgenstr,1998,169(8):45-52.
  • 10Fischer U,Baum F,Obenauer S,et al.Comparative Study in Patients with Microcalcifications:Full-field Digital Mammography vs Screen film Mammography[J].Eur Radiol,2002,12 (11):2679-2683.

共引文献20

同被引文献6

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部