期刊文献+

螺杆式热泵机组热回收量分析研究 被引量:2

Analysis of Amount on Energy Saved for Screw Heat Pump Units
下载PDF
导出
摘要 介绍了某冷机厂家螺杆式热泵机组4种热回收方案:单冷热回收双供系统、热泵机组三供系统、热泵热水机单供系统、自带经济器的热泵机组。分别计算出每种方案的热回收量大小,指出每种方案适应的气候类型和地区,分析研究后推得在保证螺杆式热泵机组主要功能的情况下最佳的热回收量。 One cooler manufacturer~ several heat recovery schemes of the screw heat pump units was introduced, such as single -heat recovery with double-supply system, the heat pump units with three-supply system, heat pump water heater with single- supply system and the heat pump unit comes with energy saver. Respectively calculate the energy saved by each heat recovery scheme. Point out the applicable climate and regions of each scheme and deduce the optimum amount of energy saved in ensured the screw heat pump units'main function circumstances.
出处 《流体机械》 CSCD 北大核心 2012年第2期81-84,共4页 Fluid Machinery
基金 湖南省高校产业化培育项目(09CY012)
关键词 螺杆式热泵机组 单冷热回收双供系统 热泵机组三供系统 热泵热水机单供系统 自带经济器的热泵机组 热回收量 screw heat pump units single-heat recovery with double-supply system the heat pump units with three-supply system heat pump water heater with single-supply system the heat pump unit comes with economizer heat recovery value
  • 相关文献

参考文献5

二级参考文献17

  • 1李觐.华南地区旅馆中央空调冷凝热在制备生活热水中的应用[J].制冷,2004,23(2):45-49. 被引量:28
  • 2尹应德,张泠,兰丽,顾登峰.余热回收型热泵在空调节能改造中的应用[J].节能与环保,2004(10):29-31. 被引量:16
  • 3龚光彩,常世钧,马扬,曾巍,林鑫.蒸汽压缩式水冷制冷机的双冷凝器热回收技术[J].建筑热能通风空调,2005,24(1):6-12. 被引量:16
  • 4电子工业部第十设计研究院.空气调节设计手册[M].北京:中国建筑工业出版社,1999
  • 5Douglas Cane R L, Blar Clemes S. Heat - recovery heat pump operating experimence [J]. ASHRAE Transactions, 1994,100(2): 165-172.
  • 6Counds D M. Performance of heat pump/desuperheater water- heating system [ J ]. ASHRAE Transactions, 1986, 92(B) : 1473 - 1482.
  • 7Cook R E. Water storage tank size requirement for residential heat pump/air - conditioner desuperheater recovery [J]. ASHRAE Transactions,1990,96(2) : 715 -719.
  • 8Gretarsson S P. Development of a fundamental based stratified thermal storage tank model for energy analysis calculation [J]. ASHRAE Transactions, 1995, 101 (1) :1213 - 1220.
  • 9Ying W M. Performance of room air conditioner used for cooling and hot water heating [J]. ASHRAE Transactions, 1989,95(2) : 441 -444.
  • 10周光辉,张超,等.带热回收装置型地下水源热泵性能的研究.河南省科技攻关项目,0624449019.

共引文献77

同被引文献13

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部