期刊文献+

高压计量装置综合误差在线统计 被引量:6

Online Statistics of Comprehensive Error for High-pressure Metering Device
下载PDF
导出
摘要 高压电能计量装置综合误差主要是通过投运前或定期对电能计量装置各部分在现场或实验室依据规程检测得到的数据进行统计,而对投运后高压电能计量装置在实际运行负荷下的综合误差却难以获得,针对这一难题,文章提出一种在线实时统计高压计量装置综合误差的新方法。 The statistics of comprehensive error for high-pressure energy metering device mainly obtains through the before operation or on a regular basis measured data on the site or laboratory, but the comprehensive error of high- pressure energy metering device after operation is difficult to obtain. Aiming at this problem, the paper puts forwards a new method of on-line and real-time statistical integrated error for high-pressure metering devices.
出处 《青海电力》 2011年第B12期33-35,共3页 Qinghai Electric Power
关键词 高压电能计量装置 综合误差 在线统计 互感器合成误差 high-pressure energy metering device comprehensive error on-line statistics transformer synthesis error
  • 相关文献

参考文献3

二级参考文献19

  • 1白洋,张建,余育植.在线CT导纳测试及其应用[J].电测与仪表,2004,41(9):52-55. 被引量:17
  • 2兰世红,万全,张建.导纳法在二次回路故障监测中的应用分析[J].电测与仪表,2007,44(3):25-29. 被引量:14
  • 3互感器带电测试应用技术指导意见2008-A[S].IEEETM技术中心,成都普莎拉科技有限公司,2008.8.
  • 4CT online analyzer (TM01), data analysis report, Inuosys Solutions Pte Ltd, Singapore 367903, 2008[Z].
  • 5Online admittance response system of current transformer, background information, Pusala Technology Co.,Ltd, www.pusala.com/transformeranalyzer. aspx[Z].
  • 6IEEE Std C37.110TM--2007 ,IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes[Z].
  • 7IEEE Std C57.13.1^TM-2006, IEEE Guide for Field Testing of Relaying Current Transformers[Z].
  • 8IEEE Std C57.13.6^TM--2005, IEEE Standard for High-Accuracy Instrument Transformers[Z].
  • 9IEEE Std C57.13.2^TM-2005, IEEE Standard Conformance Test Procedure for Instrument Transformers[Z].
  • 10JJG313-94,测量用电流互感器[S].

共引文献10