期刊文献+

Energy consumption,indoor environmental quality,and benchmark for office buildings in Hainan Province of China 被引量:1

Energy consumption,indoor environmental quality,and benchmark for office buildings in Hainan Province of China
下载PDF
导出
摘要 With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were studied through collection of verified data in site visits and field tests.The result revealed that,electricity accounted for 99.79% of the total energy consumption,natural gas 0.17%,and diesel 0.04%.The air conditioning dominated the energy use with a share of 43.18%,equipment in the particular areas 26.90%,equipment in the office rooms 11.95%,lighting system 8.67%,general service system 7.57%,and miscellaneous items 1.73%.Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW-h/m2 and lower limit of 55.26 kW-h/m2.According to ASHRAE standard(comfortable standard) and GB/T 18883-2002(acceptable standard),the indoor environmental quality of 51 sampled office buildings was classified into three ranks:good,normal and bad.With benchmark of building energy consumption combined with indoor environmental quality,it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality,and the buildings classified into normal level accounted for the maximum ratio. With rapid economy growth, building energy consumption in China has been gradually increased. The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province, a hot and humid area, were studied through collection of verified data in site visits and field tests. The result revealed that, electricity accounted for 99.79% of the total energy consumption, natural gas 0.17%, and diesel 0.04%. The air conditioning dominated the energy use with a share of 43.18%, equipment in the particular areas 26.90%, equipment in the office rooms 11.95%, lighting system 8.67%, general service system 7.57%, and miscellaneous items 1.73%. Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW.h/m2 and lower limit of 55.26 kW.h/m2. According to ASHRAE standard (comfortable standard) and GB/T 18883--2002 (acceptable standard), the indoor environmental quality of 51 sampled office buildings was classified into three ranks: good, normal and bad. With benchmark of building energy consumption combined with indoor environmental quality, it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality, and the buildings classified into normal level accounted for the maximum ratio.
出处 《Journal of Central South University》 SCIE EI CAS 2012年第3期783-790,共8页 中南大学学报(英文版)
基金 Project(2011BAJ01B05) supported by the National Science and Technology Pillar Program during the Twelfth Five-year Plan Period of China
关键词 building energy consumption BENCHMARK indoor environmental quality energy use index Hainan Province 室内环境质量 能源消耗 海南省 基准 办公大楼 中国 舒适标准 建筑能耗
  • 相关文献

参考文献4

二级参考文献17

共引文献24

同被引文献10

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部