活性污泥处理系统耐含盐废水冲击负荷性能 被引量:30

Effects of Shock Salinity Loading on Activated Sludge Treatment System
下载PDF
导出
摘要 不同含盐量的废水对运行正常的活性污泥处理系统的冲击影响试验结果表明:当处理生活污水的活性污泥系统受到的NaCl冲击负荷小于5g/L时,系统不会受到太大的影响,活性污泥的氧摄入速率(OUR)和系统的总有机碳(TOC)去除率仍能够保持正常;冲击负荷大于10g/L后,盐对活性污泥产生影响,活性污泥OUR降低约35% ,TOC去除率降低约30% The shock NaCl loading test was carried out in this experiment.Based on the experimental results obtained,following conclusions were reached:when the shocking influent with NaCl concentration less than 5g/L employed,no big influent on the biological treatment process occurred;but when the salt concentration was greater than 10g/L,oxygen uptake rate (OUR) of the sludge in the system reduced by 35% and total organic carbon(TOC) removal efficiency of the system dropped by 30%,approximately.
出处 《环境科学》 EI CAS CSCD 北大核心 2000年第1期106-108,共3页 Environmental Science
关键词 活性污泥 处理系统 含盐废水 冲击负荷 废水处理 activated sludge treatment system,saline sewage,shock loading,TOC,OUR.
  • 相关文献

参考文献5

二级参考文献11

  • 1刘洪滨.我国海水淡化和海水直接利用事业前景的分析[J].海洋技术,1995,14(4):73-78. 被引量:17
  • 2沈韫芬 章宗涉 等.微型生物监测新方法[M].北京:中国建筑工业出版社,1990.63.
  • 3郭永海.河北平原地下水环境演化规律及其与人类活动相互关系的研究.中国地质大学博士论文[M].,1993.12.
  • 4邱文芳.环境微生物学技术手册[M].北京:学苑出版社,1989.234.
  • 5谭征,走向海洋新世纪,1993年,93页
  • 6郭永海,博士学位论文,1993年,12页
  • 7沈韫芬,微型生物监测新技术,1990年,63页
  • 8邱文芳,环境微生物学技术手册,1989年,234页
  • 9刘洪滨,海洋技术,1995年,14卷,4期,76页
  • 10尤作亮,蒋展鹏,祝万鹏.海水直接利用及其环境问题分析[J].给水排水,1998,24(3):64-67. 被引量:35