摘要 The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 t*s. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A. The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 t*s. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第3期263-268,共6页 等离子体科学和技术(英文版)
关键词 PSM HV power supply control algorithm switch power supply module PSM, HV power supply, control algorithm, switch power supply module
  • 相关文献

参考文献13

  • 1Yao Lieying, Xuan Weimin, Li Huajun. 2005. Fusion Engineering and Design, 75-79:163.
  • 2Bonicelli T, Claesen R, Coletti A, et al. 2003, Fusion Engineering and Design, 66-68:543.
  • 3Zhao Lianmin, Shah Jiafang, Liu Fukun, et al. 2010, Plasma Science and Technology, 12:118.
  • 4Schmid M, Hrabal D, Piosczyk B, et al. 2009, Fusion Engineering and Design, 84:1734.
  • 5Huang Yiyun. 2006, Fusion Engineering and Design, 81:2085.
  • 6Schminke W. 1985, Brown Boveri Rev., 72:235.
  • 7Bonicelli Ti Claesenb R, Colettib A, et al. 2003, Fusion Engineering and Design, 66-68:543.
  • 8Wolfram Schminke. 1985, Brown Boveri Rev., 73:235.
  • 9Fullenbach F, Rummel. Th, Pingel H, et al. 2007, Fu- sion Engineering and Design, 82:1391.
  • 10Grimes M, Terry D, Parker R, et al. 2005, Fhsion En- gineering and Design, 74:495.

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部