摘要
详细阐述离子膜法烧碱生产中(含二次盐水、脱氯及电解系统)曾发生的问题,分析原因和采取的办法,并从中找出经验教训及预防措施。
The problems occurred in production of ion-exchange membrane caustic soda, including secondary brine system, dechlorination system and electrolysis system, were expounded. The causes and corresponding solutions were analyzed, and lessons learned from these problems were summarized as well as preventive measures.
出处
《氯碱工业》
CAS
2012年第3期11-18,共8页
Chlor-Alkali Industry
关键词
离子膜法烧碱
过滤器
树脂塔
脱氯
电解槽
事故
预防措施
ion-exchange membrane caustic soda
filter
resin tower
dechlorination
electrolyzer
accident
preventive measure