期刊文献+

自动跟踪手动触发技术256层CT诊断小儿先天性心脏病 被引量:5

Automatic tracking combined with manual triggering technique on 256-multislice CT in diagnosis of congenital heart disease in children
下载PDF
导出
摘要 目的探讨自动跟踪手动触发技术在256层CT小儿先天性心脏病(CHD)成像中的应用价值。方法对58例超声提示或临床疑诊CHD的患儿使用自动跟踪手动触发技术进行256层CT心脏成像,测量增强后左、右心室CT值,并对心脏腔室及大血管的显示进行评分。结果 58例患儿左心室平均CT值为(585.26±132.91)HU,右心室平均CT值为(592.81±146.47)HU,差异无统计学意义(P>0.05)。心脏腔室及大血管显示评分:52例(52/58,89.66%)3分,4例(4/58,6.90%)2分,2例(2/58,3.45%)1分。结论在256层CT小儿CHD成像中采用自动跟踪手动触发技术可使心脏各腔室及大血管均匀强化,在上腔静脉及右心系统无明显高浓度对比剂放射状伪影,具有良好的应用价值。 Objective To investigate the value of automatic tracking combined with manual triggering technique in 256- multislice CT diagnosis of congenital heart disease (CHD) in children. Methods Totally 58 children with suspected CHD underwent 256-MSCT. Bolus tracking was used, CT value of ventricles were measured, and the image quality of heart chambers and trunk vessels was evaluated. Then CT values were compared between right and left ventricles. Results The average CT value of left ventricle was (585.26±132.91)HU, of right ventricle was (592.81±146.47)HU (P〉0.05). For the scoring of the manifestation of heart chambers and trunk vessels, 52 cases (52/58, 89.66%) gained 3, 4 cases (4/ 58, 6.90%) gained 2 and 2 cases (2/58, 3. 45%) gained 1. Conclusion Automatic tracking combined with manual triggering technique is useful in 256-MSCT diagnosis of CHD in children.
出处 《中国医学影像技术》 CSCD 北大核心 2012年第4期710-713,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 心脏疾病 自动跟踪 手动触发 Tomography, Xray computed Heart diseases Automatic tracking Manual triggering
  • 相关文献

参考文献14

二级参考文献71

共引文献132

同被引文献40

  • 1张龙江,祁吉.对比剂肾病:一个值得关注的问题[J].中华放射学杂志,2007,41(8):882-884. 被引量:69
  • 2Lee T, Tsai IC, Fu YC, et al. Using multidetector-row CT in ne- onates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: Initial experi- ences in technical and clinical feasibility. Pediatr Radiol, 2006,36 (12) :I273-1282.
  • 3Nie P, Wang X, Cheng Z, et al. Accuracy, image quality and ra diation dose comparison of high-pitch spiral and sequential acquisi- tionon 128-slice dual-source CT angiography in children withcon- genital heart disease. Eur Radiol, 2012,22(10):2057-2066.
  • 4Paul JF, Rohnean A, Elfassy E, et al. Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source ma- chine in infants and small children with congenital heart disease. Pediatr Radiol, 2011,41(12) : 244-249.
  • 5Cheng Z, Wang X, Duan Y, et al. Low-dose prospective ECG- triggered dual-source CT angiography in infants and children with complex congenital heart disease: first experience [ J ]. Eur Radiol, 2010, 20(10):2503-2511. DOI:10.1007/sO0330-010- 1822-7.
  • 6Zhang T, Wang W, Luo Z, et al. Initial experience on the application of 320-row CT angiography with low-dose prospective ECG-triggered in children with congenital heart disease[ J]. Int J Cardiovasc hnaging, 2012, 28 ( 7 ) : 787-797. DOI: 10. 1007/ s10554-011-0005-1.
  • 7Nie P, Wang X, Cheng Z, et al. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease[J]. Eur Radiol, 2012, 22(10): 2057-2066. DOI:10. 1007/s00330-012-2479-1.
  • 8Goo HW, Park IS, Ko JK, et al. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease[ J]. Pediatr Radio1, 2005, 35 ( 8 ) :792-798. DOI : 10. lO07/s00247-005-1482-y.
  • 9Tsai IC, Lee T, Chen MC, et al. Visualization of neonatal coronary arteries on muhidetector row CT: ECG-gated verstls non- ECG-gated technique [ J ]. Pediatr Radiol, 2007, 37 (8) : 818- 825. DOI : 10. 1007/s00247-007-0512-3.
  • 10Thomas KE, Wang B. Age-specific effective doses for pediatric MSCT examatios at a {arge cb.ildren' s b.ospital, using DLP conversion coefficients: a simple estimation method [ J ]. Pediatr Radiol, 2008, 38 ( 6 ) : 645-656. DOI: 10. 1007/s00247-008- 0794-0.

引证文献5

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部