期刊文献+

隧道火灾集中排烟模式下的排烟效率研究 被引量:41

Study on smoking exhaust efficiency under central exhaust mode in tunnel fires
原文传递
导出
摘要 排烟效率是衡量集中排烟火灾通风方案排烟效果的重要指标。为合理分析排烟效率的变化特性,结合某隧道集中排烟系统设计,借助CFD技术,对设置有排烟道的隧道进行了火灾烟气控制的模拟分析,研究了排烟阀开启个数、开口面积和设置间距对双向排烟和单向排烟两种集中排烟模式下不同排烟阀设置方案中总排烟效率和各个排烟阀的排烟效率的影响。结果表明,集中排烟模式可有效将火灾烟气排出隧道。当排烟阀对称开启时,双向排烟模式下,减少排烟阀开启个数,单个排烟阀的排烟效率升高,但总排烟效率降低;当开口面积较小时,增大面积,总排烟效率升高明显,继续增大开口面积时总排烟效率升高效果减弱;增大间距有利于隧道排烟。单向排烟模式下,当排烟阀开启个数较多或开口面积较大时,距离风机最远的排烟阀排烟效率降低,并出现烟流流出排烟道的现象,排烟阀失效,可考虑在非排烟侧开启少量排烟阀,增大间距,使总排烟效率升高。 The paper is aiming to testing and measuring the effectiveness of smoke-exhausting strategies in the tunnels with the central exhaust system in regard to the smoking-exhaust efficiency.In order to improve our understanding of smoke exhaust mechanism,we have prepared a simulated model by using CFD based on the central exhausting system design of the road tunnel.To be exact,we have studied the effects of the ventilator number,the ventilation area and the design space on the total smoke-exhausting efficiency as well as the efficiency of each ventilator in various ventilation systems under two central exhaust modes of two-way and one-way smoke extraction.In this paper,we have laid out the ventilator numbers of 4,6,8,12,and the ventilation areas of 2.5, 4,6,8,10,with the spaces of 25,50,75,100 taken into full account.The results of our study show that the smoke can be extracted out of a tunnel effectively via the central exhaust system.By using the two-way ventilating mode,when the ventilation outlets are distributed on the both sides of smoke-fire outlet symmetrically,each ventilator tends to work more efficiently,however,the total efficiency of the smoke-exhaust system tends to be lower if the number of ventilator is reduced.In addition,the total efficiency is expected to rise if greater ventilation area and larger space would facilitate the smoke exhaust under the two-way exhaust mode.However,when more exhausting valves are working on or the ventilation area is larger under the one-way exhaust mode,the exhaust valves would likely fail if the smoke in the exhaust valves farthest from the fan flows into the driveway,according to which one possible solution is to open some exhaust valves on the sideway with no fans.In so doing,the total efficiency would be made higher with larger ventilation space.And,in turn,both under the two-way exhaust mode and one-way exhaust mode,the first or second exhaust valves near the fire source should be turned on.The final results should thus be made significant for establishing appropriate design scheme of the exhaust valves in the tunnel-disaster prevention.
出处 《安全与环境学报》 CAS CSCD 北大核心 2012年第2期191-196,共6页 Journal of Safety and Environment
基金 浙江省科技厅科技计划项目(2008C13041-2)
关键词 安全工程 集中排烟 数值模拟 排烟效率 排烟阀设置方案 safety engineering central smoke exhaust numerical simulation smoke exhaust efficiency vent design schemes
  • 相关文献

参考文献10

  • 1徐琳,张旭.风口特性对集中排烟隧道烟气控制效果的影响[J].暖通空调,2008,38(3):76-79. 被引量:14
  • 2张玉春,何川,曾艳华,吴德兴.特长公路隧道半横向排烟方式研究[J].公路隧道,2009(1):55-58. 被引量:5
  • 3LIN C J,CHUAH Y K.A study on long tunnel smoke extraction strate-gies by numerical simulation[J].Tunnelling and Underground SpaceTechnology,2008,23(5):522-530.
  • 4VAUQUELIN O,TELLE D.Definition and experimental evaluation ofthe smoke“confinement velocity”in tunnel fires[J].Fire Safety Jour-nal,2005,40(4):320-330.
  • 5VAUQUELIN O,MEGRET O.Smoke extraction experiments in case offire in a tunnel[J].Fire Safety Journal,2002,37(5):525-533.
  • 6JI J,LI K Y,ZHONG W,et al.Experimental investigation on influ-ence ofsmoke venting velocity and vent height onmechanical smoke ex-haust efficiency[J].Journal ofHazardous Materials,2010,177(1/2/3):209-215.
  • 7HU LH,HUO R,PENGW,et al.Onthemaximum smoketempera-ture under the ceiling in tunnel fires[J].Tunnelling and UndergroundSpace Technology,2006,21(6):650-655.
  • 8SMARDZ P.Validation of fire dynamics simulator(FDS)for forcedand natural convectionflows[D].Belfast:University ofUlster,2006.
  • 9WEN J X,KANG K,DONCHEV T,et al.Validation ofFDS for theprediction of medium-scale pool fires[J].Fire Safety Journal,2007,42(2):127-138.
  • 10DJG 08-88—2006 建筑防排烟技术规程[S].

二级参考文献11

  • 1王路威,李兆文,王琼,何嘉鹏.火灾烟气扩散数值模拟与控制研究[J].南京工业大学学报(自然科学版),2004,26(4):91-94. 被引量:9
  • 2Vauquelin O.Telle D.Definition of experimental evaluation of the smoke confinement velocity intunnel fires[J].Fire Safety,2005,40:320-330.
  • 3Vauquelin O,M6gret O Smoke extraction experiments in case of fire in tunnel[J].Fire Safety,2002,37:525-533.
  • 4Oka,Atkinson G T.Control of smoke flow intunnel fires[J].Fire Safety,1995,25:305-322.
  • 5Atkinson G T,Wu Y.Smoke control in sloppingtunnels[J].Fire Safety,1996,27:335-341.
  • 6Jones W P,Linsatedt R P.Global reaction schemes for hydrocarbon combustion[J].Combustion and Flame,1998,73:233.
  • 7Burgess D S,Grumer J,w01fhard H G Burningrates of liquid fuels in large and small open trays[C]//International Symposium on the Use of Models in Fire Research.Washington D C:National Research Council Publication,1961:403-414.
  • 8Lacroix D.The new PIARC report on fire and smoke eontrol in road tunnels[C]//3rd International Conference on safety in Road and Rail Tunnels.France,1998:185-197.
  • 9陶文铨.计算流体力学[M].北京:中国建筑工业出版社,1991.
  • 10JTJ 026.1-1999.公路隧道通风照明设计规范[S],2000.

共引文献19

同被引文献310

引证文献41

二级引证文献161

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部