摘要
针对变压器和组合电器的各种特殊连接方式,提出各设备应在未组装前进行独立试验,组装后进行耐压试验和部分试验项目,保证交接试验质量。并给出了66 kV电压等级变压器和组合电器各种特殊连接方式下的耐压试验方案,对类似现场试验提供指导。
Transformer and GIS have different connecting types in the field, but there are not corresponding test standards. The handover tests are disorder, some of the tests have big problems, would cause safety hazard to equipment operation. Some effective measures are proposed in the paper, independent tests are performed for various electric equipments before being connected, and some tests are performed after connecting, so the quality of hand-over tests is ensured. Voltage resistance test plan is also proposed for different connecting types of 66 kV transformer and GIS. It is a guide for similar tests.
出处
《东北电力技术》
2012年第3期15-18,共4页
Northeast Electric Power Technology