期刊文献+

阴极直径100mm像增强器设计与研制

Design and development of intensifier with cathode diameter of 100 mm
下载PDF
导出
摘要 设计研制一种用于宽量程扫描相机的大工作面积、高空间分辨像增强器,实现对扫描相机大面积输出图像的增强,用以解决输出图像与CCD记录系统的直接耦合匹配问题,克服了采用光纤光锥或透镜耦合到小面积像增强器时光能利用率太低的问题.对像增强器样管的实验测试结果表明,像增强器输入面积直径大于100 mm,输出图像直径30 mm,放大倍率为0.33.中心空间分辨率达30 lp/mm,边缘空间分辨率达25 lp/mm,几何畸变不大于10%.试验结果与理论设计吻合良好,性能指标满足设计要求. An intensifier with a large working area and high spatial resolution was designed and developed to meet the demands of the wide measure range streak camera. This intensifier makes it possible to directly couple the large-format output image from the camera with the CCD recording system and to intensify the image. It also avoids the light energy utilization problem when using fiber cone or lens in coupling. Via the test system we built, the tube was tested. The results show that the image intensifier has an input working diameter of more than 100 mm, an output image diameter of 30 mm, and a magnification of 0.33. The centre spatial resolution is 30 lp/mm. The marginal spatial resolution is 25 lp/mm, and the geometric distortion is less than 10%. The results are in good agreement with the design and meet application needs.
出处 《深圳大学学报(理工版)》 EI CAS 北大核心 2012年第3期236-241,共6页 Journal of Shenzhen University(Science and Engineering)
基金 国家高技术研究发展计划资助项目(2008AA0944)~~
关键词 光电子学 惯性约束核聚变 像增强器 电子光学器件 X射线 变像管 真空成像器件 扫描相机 optoelectronics inertial confinement fusion image intensifier electro-optical devices X-ray tube vacuum imaging device streak camera
  • 相关文献

参考文献7

二级参考文献31

  • 1郭金川.X光机中的物理问题及数字X射线成像研究[M].西安:中国科学院西安光学精密机械研究所,1999..
  • 2廖华.中子扫描变像管超快诊断技术[M].西安:中国科学院西安光学精密机械研究所,2000..
  • 3李冀.多功能新型扫描变像管及相机的理论与实验研究[M].西安:中国科学院西安光学精密机械研究所,2000..
  • 4屈军乐.荧光寿命成像显微技术的理论与实验研究[M].西安:中国科学院西安光学精密机械研究所,1998..
  • 5李淑红.分幅电子显微技术的理论与实验研究[M].西安:中国科学院西安光学精密机械研究所,1998..
  • 6牛憨笨.散射介质中的光子学问题[J].光子学报,1999,28(1):23-23.
  • 7[5]Pollehn H K. Performance and reliability of third generation image intensifiers[J]. Advances in Electronics and Electron Physics, 1985,64A: 61-69.
  • 8[6]Leon A Bosch. Image intensifiers tube performance is what matters[A]. Image Intensifers and Applications Ⅱ, Proceedings of SPIE[C]. 2000,4128. 65-78.
  • 9[7]Van Geest L K, Stoop K W J. Super inverter image intensifier[J].Advances in Electronics and Electron Physics,1985,64A:93-100.
  • 10[8]Estrera Joseph P, Bender E J, Adriana Giordana,et al. Long lifetime generation Ⅳ image intensifiers with unfilmed microchannel plate[A]. Image Intensifers and Applications Ⅱ, Proceedings of SPIE[C]. 2000,4128.46-53.

共引文献67

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部