期刊文献+

不同效应室靶浓度瑞芬太尼对患者异丙酚镇静效应的影响 被引量:7

Effects of different target effect-site concentrations of remifentanil on propofol sedation in patients
下载PDF
导出
摘要 目的研究瑞芬太尼不同效应室靶浓度对患者异丙酚镇静效应的影响。方法将75例择期全麻手术患者随机分为A、B、C、D、E共5组,脑电双频指数(BIS)降为50时,记录异丙酚效应室靶浓度、异丙酚总用量以及所需时间,以及患者意识消失时BIS值和异丙酚效应室靶浓度。结果 5组患者麻醉诱导开始各基础值无显著差异。BIS值降为50时C、D、E组分别与A组、B组相比,异丙酚效应室靶浓度、异丙酚总用量以及所需时间均明显减少;患者意识消失时C、D、E组分别与A组、B组相比,异丙酚效应室靶浓度明显降低,BIS值明显增高。结论瑞芬太尼与异丙酚复合用于全身麻醉时适宜的效应室靶浓度为4 ng/mL。 Objective To study the effects of different target effectsite concentrations of remifentanil on propofol sedation.Methods A total of 75 patients who received elective surgery under general anesthesia were randomly divided into groups A,B,C,D and E.When bispectral index(BIS) reduced to 50,the propofol effect,target effect-site concentrations,total propofol dosage,time required,and BIS values and target concentrations when patients lost consciousness of propofol effect were recorded.Results The basic values at the onset of anesthetic induction showed no significant differences between the 5 groups.As the BIS values dropped to 50,the effect of propofol target concentration,propofol dosage and time required in groups C,D,E were significantly less than those in groups A and B.When patients lost consciousness,compared with the groups A and B,the effect of propofol target concentration was significantly lower,and the BIS value was significantly higher in groups C,D and E.Conclusion The optimal target concentration is 4 ng/mL when combined remifentanil-propofol is administered for general anesthesia.
出处 《实用临床医药杂志》 CAS 2012年第7期39-41,共3页 Journal of Clinical Medicine in Practice
基金 中国高校医学期刊临床专项资金(41220006)
关键词 瑞芬太尼 异丙酚 麻醉 镇静 脑电双频指数 remifentanil propofol anesthesia sedation bispectral index
  • 相关文献

参考文献9

二级参考文献42

  • 1邱献华,王海学.新辅助化疗加手术治疗乳腺癌的临床观察[J].现代肿瘤医学,2006,14(9):1071-1073. 被引量:8
  • 2于布为.理想麻醉状态与麻醉深度监测[J].现代临床医学生物工程学杂志,2006,12(4):305-307. 被引量:26
  • 3SigaLovsky N. Awareness under generaL anesthesia [J ]. AANA J, 2003, 71(5): 373.
  • 4Kreuer S, WiLheLm W. The Narcotrend monitor[J]. Best Pract Res CLin AnaesthesioL, 2006, 20:111.
  • 5Kreuer S, BiedLer A, Larsen R, et al. Narcotrend monitoring aLLows faster emergence and a reduction of drug consumption in pmpofoL remifentaniL anesthesia[J ]. AnesthesioLogy, 2003, 99: 34.
  • 6Schmidt G N, Bisehoff P, StandL T, et al. Narcotrend and bispectraL index monitor are superior to classic eLectroencephaLographie parameters for the assessment of anesthetic states during propofoL- remifentaniL anesthesia[J]. Anesthesiology, 2003, 99: 1072.
  • 7Renna M, Venturi R. BispectraL index and anaesthesia in the eLderLy[J]. Minerva AnestesioL, 2000, 66: 398.
  • 8Smith W D, Dutton R C, Smith N T. A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area[J]. Stat Med, 1996, 15 (11): 1199.
  • 9Smith W D, Dutton R C, Smith N T. Measuring the performance of anesthetic depth indicators [J ]. AnesthesioLogy, 1996, 84(1): 38.
  • 10Drummond J C. Monitoring depth of anesthesia: with emphasis on the appLication of the bispectraL index and the middLe Latency auditory evoked response to the prevention of recaLL[J]. AnesthesioLogy, 2000, 93(3): 876.

共引文献25

同被引文献119

引证文献7

二级引证文献77

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部