摘要 目的采用meta分析的方法评价主动自锁托槽与被动自锁托槽摩擦力的大小。方法检索Pubmed、荷兰医学文摘(Embase)、Google文献检索、中国期刊网(CNKI)和中国生物医学文献数据库(CBMdisc)数据库,搜集从建库至2011年9月公开发表的关于主动、被动自锁托槽摩擦力的随机对照实验。利用Revman4.2软件及Stata 7.0软件对纳入meta分析的研究进行定量分析,以评价主动、被动自锁托槽与不锈钢丝结合时滑动摩擦力的大小。结果有6项研究适合做meta分析。结果显示:主动、被动自锁托槽在与圆丝结合时,摩擦力的大小没有统计学差异;而与不锈钢方丝结合时主动自锁托槽的摩擦力大于被动自锁托槽,差异具有统计学意义。结论在矫治初期,主动、被动自锁托槽摩擦力没有统计学差异,而在矫治后期,主动自锁托槽摩擦力大于被动自锁托槽。 Objective To compare the frictions of active self-Ligating brackets(ASB) and passive self-ligating brackets(PSB).Methods An electronic search of Pubmed,Embase,Google,CNKI and CBMdisc with no restrictions in publication status and publication language was performed for articles published from 1966 to Sep 2011.Data were analysed with Revman 4.2 software and Stata 7.0 software to evaluate the frictions of the ASB and PSB.Results Only 6 randomized controlled trials(RCT) were suitable for the meta-analysis.From the limited number of articles in meta-analysis,we concluded that when ASB and PSB were combined with round archwires,there were no statistical differences in frictions,but when ABS and PSB were combined with rectangular archwires,there was statistical differences in frictions.Conclusions At the early stage of the orthodontic treatment,there were no statistical differences between ASB and PSB,while statistical differences in frictions existed between ASB and PSB at the later stage of the treatment.
出处 《口腔医学》 CAS 2012年第5期257-262,共6页 Stomatology
基金 国家自然科学基金(30973361) 江苏高校优势学科建设工程资助项目
关键词 主动自锁托槽 被动自锁托槽 摩擦力 META分析 active self-ligating backets passive self-ligating brackets friction meta-analysis
  • 相关文献

参考文献41

  • 1Frank CA,Nikolai RJ.A comparative study of frictional resistances between orthodontic bracket andarch wire[J].Am J Orthod,1980,78(6):593-609.
  • 2Khambay B,Millett D,McHugh S.Evaluation of methods of arch-wire ligation on frictional resistance[J].Eur J Orthod,2004,26(3):327-332.
  • 3Henao SP,Kusy RP.Evaluation of the frictional resistance of con-ventional and self-ligating bracket designs using standardized arch-wires and dental typodonts[J].Angle Orthod,2004,74(2):202-211.
  • 4Read-Ward GE,Jones SP,Davies EH.A comparison of self-ligatingand conventional orthodontic bracket systems[J].Br J Orthod,1997,24(4):309-317.
  • 5Berger JL.The influence of the SPEED bracket's self-ligating de-sign on force levels in tooth movement:a comparative in vitro study[J].Am J Orthod Dentofacial Orthop,1990,97(3):219-228.
  • 6Voudouris JC.Interactive edgewise mechanisms:form and functioncomparison with conventional edgewise brackets[J].Am J OrthodDentofacial Orthop,1997,111(2):119-140.
  • 7Tidy DC.Frictional forces in fixed appliances[J].Am J OrthodDentofacial Orthop,1989,96(3):249-254.
  • 8Garner LD,Allai WW,Moore BK.A comparison of frictional forcesduring simulated canine retraction of acontinuous edgewise archwire[J].Am J Orthod Dentofacial Orthop,1986,90(3):199-203.
  • 9Pratten DH,Popli K,Germane N,et al.Frictional resistance of ce-ramic and stainless steel orthodontic brackets[J].Am J OrthodDentofacial Orthop,1990,98(5):398-403.
  • 10Tselepis M,Brockhurst P,West VC.The dynamic FRSS betweenorthodontic brackets and archwires[J].Am J Orthod DentofacialOrthop,1994,106(2):131-138.

二级参考文献27

  • 1丁鹏(综述),周彦恒(审校),林久祥(审校).白锁托槽矫治器的发展、分类及特点[J].口腔正畸学,2006,13(1):40-43. 被引量:35
  • 2谭忠荣,叶翁三杰.自锁托槽和传统直丝弓托槽弓丝结扎时间的对比研究[J].口腔医学研究,2007,23(4):445-447. 被引量:13
  • 3Franco DJ,Spiller RE,Fraunhofer JA.Frictional resistances using Teflon-coated ligatures with various bracket-archwire combinations[J].Angle Orthod,1995,65(1):63-72.
  • 4Drescher D,Bourauel C,Schumacher HA.Friction forces between bracket and archwire[J].Am J Orthod Dentofac Orthop,1989,96:397-404.
  • 5Edwards GD,Davies EH,Jones SP,et al.The ex vivo effect of ligation technique on the static frictional resistance of stainless steel brackets and archwires[J].Br J Orthod,1995,22(2):145-153.
  • 6Downing A,Mccabe J.A study of frictional forces between brackets and archwires[J].Br J Orthod,1994,21(4):349-357.
  • 7Thorstenson GA,Kusy RP.Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state[J].Am J Orthod Dentofac Orthop,2002,121(5):472-482.
  • 8Pizzoni L, Rauholt G, Melsen B. Frictional Forces Related To Self-Ligatlng Brackets. Eur J Orthod. 1998, 20 : 283- 291
  • 9Glonys Thorstenson, Robert P Kusy. Comparison Of Resistance To Sliding Between Different Self-Ligating Brackets With Second-Order Angulations In The Dry And Saliva States.Am J orthod dentofacial orthop,2002; 121:472-82
  • 10Sandra P. Henao ,Robert P. Kusy. Evaluation Of The Friction Resistance Of Conventional And Self-Ligating Bracket Designs Using Standardized Archwires And Dental Typodonts. Angle Orthod Am J orthod dentofacial orthop2004 ; 74 : 202- 211

共引文献34