期刊文献+

床旁超声测量视神经鞘直径对颅脑损伤患者颅内压增高的诊断价值 被引量:11

Diagnosis Value of Optic Nerve Sheath Diameter Measured by Bedside Ultrasound for Increased Intracranial Pressure in Patients with Traumatic Brain Injury
原文传递
导出
摘要 [目的]探讨利用床旁超声测量视神经鞘直径在颅脑损伤患者中检出颅内压(ICP)增高者的应用价值.[方法]35例颅脑损伤(ICP正常22例,ICP增高13例)患者及10名健康志愿者行床旁超声检查测量视神经鞘直径,并对颅脑损伤患者进行ICP测定.比较三组之间视神经鞘直径,计算视神经鞘直径与ICP的相关性,利用ROC曲线探究预测ICP增高的最佳阈值及准确性.[结果]ICP增高组视神经鞘直径显著高于ICP正常组及对照组(P〈0.05),ICP正常组视神经鞘直径与对照组差异无统计学意义(P〉0.05),视神经鞘直径与ICP之间存在正相关关系(r=0.733,P〈0.01).ROC曲线显示视神经鞘直径≥5.0 mm作为判断标准效果最佳,此时敏感度86.4%(19/22)、特异度84.6%(11/13)、准确度85.7%(30/35)、阳性预测值90.5%(19/21)、阴性预测值78.9%(11/14).[结论]床旁超声测量视神经鞘直径能够较好预测ICP水平,当视神经鞘直径≥5.0mm提示ICP增高. [Objective] To explore the diagnosis value of bedside ultrasound for measuring optic nerve sheath diameter in increased intracranial pressure of patients with traumatic brain injury. [Methods]Thirtyfive patients with traumatic brain injury and ten healthy volunteer underwent bedside ultrasound for measuring optic nerve sheath diameter. Intracranial pressure of patients with traumatic brain injury was measured. Optic nerve sheath diameter among three groups was compared. The association between optic nerve sheath diameter and intracranial pressure was assessed. Receiver operating curve(ROC) was used to predict the best threshold of increased intracranial pressure and accuracy. [Results]Optic nerve sheath diameter in increased intracranial pressure group was significantly higher than that on normal intracranial pressure group and control group( P 〈0.05), but there was no significant difference between normal intracranial pressure group and control group ( P 〉0.05). Optic nerve sheath diameter was positively correlated with intracranial pressure(r=0. 733, P 0.01). ROC showed that optic nerve sheath diameter≥5.0mm as the efficacy evaluation was the best, and its sensitivity, specificity, accuracy and positive and negative predictive value were 84.4% (19/22), 84.6% (11/ 13), 85.7%(30/35), 90.5%(19/21) and 78.9%(11/14), respectively. [Conclusion] Bedside ultrasound for measuring optic nerve sheath diameter can better predict the level of intracranial pressure. Optic nerve sheath diameter≥5.0mm indicates increased intracranial pressure.
出处 《医学临床研究》 CAS 2012年第4期707-709,713,共4页 Journal of Clinical Research
关键词 脑损伤/超声检查 颅内压 Brain injuries/US intracranial pressure
  • 相关文献

参考文献17

  • 1Noble KA. Traumatic brain injury and increased intracranial pressure[J]. J Perianesth Nurs ,2010,25(4) :242-248.
  • 2Soldatos T, Karakitsos D, Chatzimiehail K, et al. Optic nerve sonography in the diagnostic evaluation of adult brain injury[J]. Crit Care ,2008,12(3) :R67.
  • 3Dubourg J. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure[J]. Intensive Care Med ,2011,37(7):1059 1068.
  • 4Major R, Girling S, Boyle A. Ultrasound measurement of op- tic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure[J]. Emerg Med J , 2011,28 (8) :679-681.
  • 5胡涛,曾祥富,张晓海,金海泉.高渗盐水降低颅脑损伤后高颅内压的临床效果观察[J].中国临床神经外科杂志,2010,15(5):305-306. 被引量:15
  • 6Soldatos T, Chatzimichail K, Papathanasiou M, et al . Optic nerve sonography: a new window for the non-invasive evalua tion of intraeranial pressure in brain injury[J]. Emerg Med J, 2009,26(9) :630-634.
  • 7Kimberly HH, Noble VE. Using MRI of the optic nerve sheath to detect elevated intracranial pressure[J]. Crit Care , 2008,12(5):181.
  • 8Hamilton DR, Sargsyan AE, Melton SL, et al . Sonography for determining the optic nerve sheath diameter with increas ing intracranial pressure in a porcine model[J]. J Ultrasound Med ,2011,30(5) :651-659.
  • 9Hansen HC, Lagreze W, Krueger O, et al . Dependence of the optic nerve sheath diameter on acutely applied subarach- noidal pressure - an experimental ultrasound study[J]. Acta Ophthalmol ,2011,89(6) :e528 -532.
  • 10Dubourg J, Javouhey E, Geeraerts T, et al . Ultrasonogra- phy of optic nerve sheath diameter for detection of raised in- tracranial pressure: a systematic review and meta-analysis [J]. Intensive Care Med ,2011,37(7) : 1059-1068.

二级参考文献7

共引文献14

同被引文献75

  • 1杨勇,杨义,王任直.颅内压监测技术的进展[J].中国微侵袭神经外科杂志,2008,13(6):284-286. 被引量:39
  • 2曾高,焦风,李运海,栾文忠,梁冶矢.用数学模型实现无创颅内压监测的现状与应用前景[J].中国脑血管病杂志,2007,4(9):418-420. 被引量:8
  • 3Bellomo R, Ronco C, Kellum JA, et al. Acute renal failure - defini- tion, outcome measures, animal models, fluid therapy and informa- tion technology needs:the Second International Consensus Confer- ence of the Acute Dialysis Quality Initiative (ADQI) Group. Acute Dialysis Quality Initiative workgroup. Crit Care, 2004 , 8 (4) : R204-212.
  • 4Ibolja Cernak, Linda J Noble-Haeusslein. Traumatic brain injury: an overview of pathobiology with emphasis on military populations. J Cereb Blood Flow Metab,2010,30(2) :255-266.
  • 5Beare NA, Kampondeni S, Glover S J, et al. Detection of raised in- tracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children [J]. Trop Med Int Healt, 2008, 13(11): 1400-1404.
  • 6Hansen HC, Helmke K, Kunze K. Optic nerve enlargement in the acute intraeranial hypertension [J]. Nero-ophthalmology, 1994, 14: 345-354.
  • 7Malayeri AA, Bavarian S, Mehdizadeh M. Sonographic evaluation of optic nerve diameter in children with raised intracranial pressure [J]. J Uitrasound Med, 2005, 24(2): 143-147.
  • 8Tayal VS, Neulander M, Norton HJ, et al. Emergency department so- nographhic measurement of optic nerve sheath diameter to detect findings of increased intraeranial pressure in adult heat injury pa- tients [J']. Ann Emerg Med, 2007, 49(4): 508-514.
  • 9Goel RS, Goyal NK, Dharap, et al. Utility of optic nerve ultrasonog- raphy in head injury [J]. Injury, 2008, 39(5): 519-524.
  • 10Blaivas, Thcodoro D, Sierzcnski PR. Elevated intracranial pressure detected by bedside emergency ultrasonography of the opic nerve sheath [J]. Acad Emerg Med, 2003, 10 (4): 376-381.

引证文献11

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部