期刊文献+

提高航天器超声检漏灵敏度的方法研究 被引量:3

Improvement of sensitivity of ultrasonic leak testing for spacecraft
下载PDF
导出
摘要 应用超声进行航天器舱体及管道系统检漏是一种可快速定位漏点的无损检测方法,从试验方法及信号处理上可以有效提高各种工况下的检漏灵敏度。文章对非接触超声检漏提高有效湍流强度增强超声信号和接触超声检漏改变信号带通频率这两种方法进行了试验研究。结果显示,采用这两种方法均能增强有效信号强度,提高检漏灵敏度。 Ultrasonic leak testing is an efficient non destructive testing method for locating leak sources in spacecraft and pipe systems,and its sensitivity can be improved by adopting appropriate methods of experiment and signal processing.Two kinds of experiments are carried out to find ways that may improve the leak tesing sensitivity: one is to enhance the effective turbulence intensity in a noncontact method,the other is to switch the threshold frequency band in a contact method.The results show that the two methods can both increase the effective signal intensity,thus enhance the leak tesing sensitivity.
作者 郭欣 闫荣鑫
出处 《航天器环境工程》 2011年第4期372-374,共3页 Spacecraft Environment Engineering
基金 载人航天三期关键技术项目
关键词 超声波 检漏 湍流噪声 检漏灵敏度 ultrasonic wave leak testing turbulence noise leak testing sensitivity
  • 相关文献

参考文献5

二级参考文献12

共引文献21

同被引文献19

  • 1喻新发,闫荣鑫,邵容平,孟冬辉,郭欣.空间站在轨密封检漏技术研究[J].航天器环境工程,2008,25(2):177-182. 被引量:12
  • 2闫荣鑫.用指向性真空规进行空间站结构泄漏监测的设想[J].航天器环境工程,2006,23(2):75-79. 被引量:6
  • 3喻新发,闫荣鑫,孟冬辉.差压检漏系统压力与温度响应的计算分析[J].航天器环境工程,2006,23(3):175-180. 被引量:7
  • 4喻新发,闫荣鑫,孟冬辉,郭欣.差压检漏系统仿真试验研究[J].航天器环境工程,2006,23(5):297-301. 被引量:2
  • 5李强;赵伟.MATLAB数据处理与应用,2001.
  • 6REUSSER R, HOLI.AND S D, ROBERTS R A, et al. Array-based acoustic leak location in spacecraft structures [C]. AIP Conference Proceedings, Portland, Oregon, USA, July 30-August 4, 2006, 894(1).. 1540 -1547.
  • 7HOLLAND S D, ROBERTS R, CHIMENT1 D E, et al. Two-sensor ultrasonic spacecraft leak detection using structure-borne noise [R]. Acoustics Research Letters Online, 2005, 6(2), 63-105.
  • 8HOLLAND S D, ROBERTS R, CHIMENTI D E, et al. Leak detection in spacecraft using structure-borne noise with distributed sensors [R]. Applied Physics Letters, 2005, 86(17) 174105.
  • 9SONG JUNHO, HOLLAND D STEPHEN, CHIMENTI D E. A spherically focused capacitive-film ai>coupled transducer [C]. AIP conference, Brunswick, Maine, USA, July 31-August 5, 2006, 820.. 908-915.
  • 10VHOLLAND S D, ROBERTS R, CHIMENTI D E, et al. An ultrasonic array sensor for spacecraft leak direction finding [J]. Ultrasonics, 2006, 45:121- 126.

引证文献3