摘要 对于开式地表水源热泵,取水能耗是决定系统节能性的关键因素。在水源热泵机组能耗模型、取水能耗模型等的基础上建立了开式地表水水源热泵系统的能效耦合模型。基于节能率及水泵能耗的规律特点计算得到了不同的冷却塔出水温度下,不同水泵扬程下的动态取水温度限值,建立了开式地表水水源热泵动态取水温度限值的计算方法。并计算得到不同工况条件下的地表水源热泵系统相对传统空调的节能率。 Energy consumption of water intake is one of the key factors for energy saving in the application of the open-loop surface water heat pump system. An energy efficiency ratio coupling model for open-loop surface water source heat pump systems was established on the basis of the energy consumption model for the water intake and the heat pump units. According to energy saving rate and regulation of energy consumption of water intake, dynamic temperature limits of water intake in different water supply temperature of cooling tower and different pump head were proposed so as to find a calculation method of temperature limits of water intake of open-loop surface water heat pumps. Moreover, the energy saving rate of surface water source heat pump systems compared with traditional air-conditioning systems under various condition was also calculated.
出处 《土木建筑与环境工程》 CSCD 北大核心 2012年第3期103-109,共7页 Journal of Civil,Architectural & Environment Engineering
基金 科技部“十一五”科技攻关项目(2006BAJ01A06) 重庆市自然科学基金计划资助项目(CQ KSTC,2010BB4235)
关键词 开式地表水源热泵 取水温度限值 动态 节能率 open-loop surface water source heat pumps temperature limit of water intake dynamie energy saving rate
  • 相关文献

参考文献14

二级参考文献77

共引文献138

同被引文献21

  • 1王洲,杨尚一,李树一,刘宁然,魏巧兰.水源热泵系统在沈阳地区某办公大楼项目的适用性探究[J].暖通空调,2022,52(S01):85-88. 被引量:2
  • 2陈晓,彭建国,张国强,林宣军,林汉柱.地表水在供冷供热中应用的现状及分析[J].建筑热能通风空调,2006,25(2):25-27. 被引量:6
  • 3Rackliffe GB,Schabel KB. Groundwater heat pump demonstration results for residential applications in New York State [ J ]. ASHRAE Transactions, 1986,92 (2A) : 3 - 17.
  • 4Aittomaki A. Lakes as a heat source in cold climate [ C ]// Proceedings of the 21st IIR International Congress of Refrigeration, Washington,2003 : 88 - 92.
  • 5吴艳菊.地表水源热泵适宜性综合评价及规划研究[D].重庆:重庆大学,2008.
  • 6Yong Wang,Zhiyun Wang, Xiangzhao Fu. The design of a novel heat exchanger without water treatment[ J]. Advances in Building Materials ,2011,168 ( 2 ) : 1432 - 1437.
  • 7Yong Wang, Kelvin KL Wong, Qing-hua Liu, et al. Improvement of energy efficiency for an open-loop surface water source heat pump system via optimal design of water-intake [ J ]. Energy and Buildings,2012,51 (8) :93 - 100.
  • 8Yong Wang, Binquan Jiao. Environmental impacts of lake-water source heat pump systems on receivin$ waters in southern areas of China [ J ]. Chemistry and Environment,2011,12 ( 2 ) : 1 - 6.
  • 9苏阳.湖水源热泵系统对水体环境影响评价研究[D].重庆重庆大学,2010.
  • 10王勇,肖益民,陈金华,刘勇.开式地表水地源热泵取排水方式研究[J].暖通空调,2008,38(10):124-127. 被引量:13

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部