摘要
为了研究再生混凝土的抗冻融性能,进行了不同再生粗骨料和不同再生细骨料取代率的54个立方体试块和27个棱柱体试件的抗冻融性能试验。基于试验,分析了分别经25次、50次、75次和100次冻融循环后,各阶段棱柱体试件的表观特征、质量损失率、相对动弹性模量改变量以及立方体试块的抗压强度损失率;研究了"试件质量损失率-冻融循环次数"、"试件相对动弹性模量改变量-冻融循环次数"的变化规律;提出了适于寒冷地区建造房屋结构的再生混凝土骨料及其取代率。研究表明,再生粗骨料取代率为50%、细骨料为普通砂的试件,经100次冻融循环后,其表观特征、质量损失率、相对动弹性模量改变量均与普通混凝土相差不多,经合理设计,仅掺入不高于50%的再生粗骨料的再生混凝土可用于寒冷地区混凝土房屋结构。
In order to study the freeze-thaw durability of the recycled concrete, the fast freeze-thaw cycle tests were carried out on fifty-four cube specimens and twenty-seven prism specimens with different replacement ratios of recy- cled coarse or fine aggregate. Based on the experiment, appearance features, mass loss rates, changes of relative dynamic elastic modulus of prism specimens, and loss rates of compression strength of the cube specimens for 25, 50, 75, and 100 freeze-thaw cycles respectively were analyzed. The relationships of the mass loss rate and the rela- tive dynamic elastic modulus of specimens with the increase of freeze-thaw cycles were analyzed as well. The recy- cled aggregate and its replacement ratio, which are suitable for building structures in cold area, were proposed. Research shows that after 100 freeze-thaw cycles, the specimens with 50% replacement ratio of recycled coarse ag- gregate and natural sand fine aggregate do not make much difference compared with ordinary concrete in appearance features, mass loss rate and the relationship of relative dynamic elastic modulus, So through reasonable design, the recycled concrete with no more than 50% replacement rate of recycled coarse aggregate can be used for building structures in cold areas.
出处
《自然灾害学报》
CSCD
北大核心
2012年第3期184-190,共7页
Journal of Natural Disasters
基金
国家十二五科技支撑计划课题(2011BAJ08B02)
关键词
再生混凝土
冻融循环
力学性能
试验研究
recycled concrete
freeze-thaw cycle
mechanical property
experimental study