超声洁牙时气溶胶与飞沫的检测分析 被引量:11

Detection and analysis of aerosols and droplets in the ultrasonic scaler
下载PDF
导出
摘要 目的探讨2种不同的干预措施对洁牙时气溶胶和飞沫在不同距离时的污染程度。方法采用空气自然沉降法进行气溶胶和飞沫采样,试验组使用具有吸唾功能的开口器,对照组使用常规强负压吸唾管,在患者头部高度的正前方、左侧、右侧各50、100、150 cm处放置营养琼脂平板共9块,在洁牙开始前,开始后30、60 min,结束后10 min分别采样4次;并在结束后对医生的口罩和办公台面进行物体表面采样,进行菌落数计数和菌种分类鉴定。结果在相同方位的50、100 cm距离处洁牙30、60 min后的样本细菌菌落数上,试验组和对照组间的差异有统计学意义(P<0.01);在相同方位的150 cm处洁牙30、60 min后的样本细菌菌落数上,试验组和对照组间的差异有统计学意义(P<0.05);试验组医生的口罩与办公台面细菌落数分别为(1 493±35.73)、(1 538±71.85)CFU.m-3,明显低于对照组的(2 828±59.51)、(3 073±74.27)CFU.m-3;气溶胶和飞沫中查见最常见的病原菌:嗜麦芽糖寡养单胞菌、人苍白杆菌、微球菌属等。结论使用具有吸唾功能的开口器能更有效地控制气溶胶和飞沫的传播。 Objective To determine two different interventions and understand pollution levels of aerosols and droplets in the air at different distances. Methods Used the air natural sedimentation to take sample of the aerosols and droplets, experimental group used the opening with aspirator function, control group used the strong negative pressure to attract intervention. Fall out samples were collected with nutritious agar plates placed in nine different spots, in front, left, right 50, 100, 150 cm from head height of the patient. Took the samples for four times, before cleaning teeth, 30 rain and 60 rain after the start, 10 min after cleaning teeth; took the samples of doctor's mask and office table surface at the end, and appraisalled the number of colonies and species classification. Results There were significant differences between experimental and control groups, samples of which had bacterial colony counts, which were collected at 30, 60rain after cleaning teeth, 50, 100 cm in the same orientation. The difference was statistically significant (P〈0.01). There were significant differences between the experimental and control groups, samples of which had bacterial colony counts, which were collected at 30, 60 min after cleaning teeth, 150 cm in the same orientation. The difference was statistically significant (.P〈0.05). Bacterial colonies of doctor's masks and office countertops of experimental group were (1 493±35.73), (1 538±71.85) CFUm-3, significantly lower than the control group, bacterial colonies of which were (2 828±59.51), (3 073±74.27) CFU .m-3. The found pathogenic microorganisms were identified as Stenotrophomonas mahophilia, Ochrobactrum anthropi, micrococcus and so on. Conclusion Aspirator openings can more effectively control the spread of aerosols and droplets.
出处 《国际口腔医学杂志》 CAS 2012年第4期449-452,共4页 International Journal of Stomatology
基金 深圳市科技计划基金资助项目(201103261)
关键词 口腔诊室 气溶胶 飞沫 医院感染 dental clinic: aerosol droplet nosocomial infections
  • 相关文献

参考文献3

二级参考文献33

共引文献32

同被引文献84

引证文献11

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部