摘要
通过分析电晕放电的原因和危害,结合实际在水电站中大量使用的高压发电机电晕放电实例,说明使用传统的防电晕措施费工费时;通过不断摸索,采用了行之有效的新的处理措施,并在实际应用中进行了多年的检验,效果良好.
By analysis of the causes and harm of corona discharge,combined with the actual hydropower station in the heavy use of the high voltage generator of corona discharge,the paper illustrates that the traditional corona proof measures are time-consuming.Thus,through years of practical research the author finds out a new method of corona protection which has been proved to be more effective.
出处
《宁德师范学院学报(自然科学版)》
2012年第2期181-183,共3页
Journal of Ningde Normal University(Natural Science)
关键词
高压电机
电晕放电
防电晕
措施
效果
high-voltage generator
corona discharge
corona protection
methods