期刊文献+

基于无线刺激与遥测系统的心房颤动动物模型 被引量:7

An animal model of atrial fibrillation by means of stimulation and telemetry system based on wireless
下载PDF
导出
摘要 目的探索一种可控、可靠、安全的心房颤动(简称房颤)动物模型的建立方法。方法自主设计并制作一种基于Microchip公司的PIC18(Peripheral Interface Controller,外围接口控制器)系列单片机和TI公司的RF(Radio Frequency,射频)无线收发芯片CC1101 CC1101(Chipcon公司)的植入式遥测刺激器,植入比格犬背部,记录电极留置腹侧皮下,刺激电极缝合于左心耳上,在犬清醒自由的条件下,通过计算机专用心电软件连续监测体表II导联心电信号,并发放间歇(刺激1 s,暂停2 s)高频(频率30 Hz)阈上(强度2 mA,脉宽5 ms)刺激,若间歇期内出现房颤,则人为干预中止刺激,若转为窦性心律,则继续刺激。结果植入式遥测刺激器在体外可稳定工作(包括采集模拟心电信号和发放刺激)30天,植入犬体内刺激3天后可诱导出房颤,持续时间最长达8 h。结论应用植入式遥测刺激器是建立房颤动物模型的可行性方法之一。 Objective To explore a controllable, reliable and safe method to establish an animal model of atrial fibrilla- tion. Method We designed an implantable telemetry and stimulator based on Microchip's microcontroller of PIC 18 se- ries and TI's CC1101 RF wireless transceiver chip independently ,which we implanted into the back of the Beagle. The re- cording electrodes were left under the ventral skin while the stimulating electrodes were sutured on the surface of the left at- rial appendage. We monitored the surface Ⅱ lead electrocardiograph continuously through computer software and emitted intermittent (to stimulate 1 s and pause 2 s), high frequency (30 Hz), and up the threshold (intensity of 2 mA and pulse width of 5 ms) stimulations. If atrial fibrillation was observed, we suspended the stimulations, otherwise we continued the stimulations. Results In vitro, the implantable telemetry and stimulator could run stably for 30 days, including record- ing analogous electrocardiograph and emiting stimulations. Atrial fibrillation was successfully induced in the survival Beagle after 3 days stimulating. The longest duration of atrial fibrillation was 8 hours. Conclusion Implantable telemetry and stimulator can be feasible in the establishment of animal model of atrial fibrillation.
出处 《中国心脏起搏与心电生理杂志》 2012年第3期241-245,共5页 Chinese Journal of Cardiac Pacing and Electrophysiology
基金 上海市科委资助项目(项目编号:09140901800)
关键词 心血管病学 植入式 程控 遥测 心房颤动 模型 Cardiology Implantable Programmed Telemetry Atrial fibrillation Model
  • 相关文献

参考文献6

  • 1Wijffels MC, Kirchhof C J, Dorland R, et al. Atrial fibrillation begets atrial fibrillation: a study in awake chronically instrumented goats [ J ]. Circulation, 1995,92 ( 7 ) : 1 954.
  • 2Ausma J, Wijffels M, Thone F, et al. Structural changes of atrial myo- cardium due to sustained atrial fibrillation in the goat [ J ]. Circula- tion,1997,96(9) :3 157.
  • 3Luo Z, Sonkusale SS. A novel BPSK demodulator for biological im- plants[J]. IEEE Trans Circuits Syst I, 2008, 55(6) :1 478.
  • 4Ghovanloo M, Atluri S. An integrated full-wave CMOS rectifier with built-in back telemetry for RFID and implantable biomedical appli- cations[ J]. IEEE Trans Circuits Syst I, 2008, 55(10) : 3 328.
  • 5Liang CK, Chen JJ, Chung CL. An implantable bi-directional wire- less transmission system for transcutaneous biological signal recording [J]. Physiol Meas, 2005, 26:83.
  • 6Donaldson N, Zhou L, Perkins TA, et al. Implantable telemeter for long-term electroneurographic recordings in animals and humans [J]. Med Biol Eng Comput, 2003, 41:654.