期刊文献+

320排动态容积CT诊断颈内动脉颅内段动脉瘤的价值 被引量:9

Diagnostic value of 320-detector row CT in patients with intracranial internal carotid artery aneurysms
下载PDF
导出
摘要 目的:评价320排动态容积CT在颈内动脉颅内段动脉瘤诊断中的价值。方法:2010年4月~2010年11月间经320排动态容积CT检出颈内动脉颅内段动脉瘤48例,回顾性分析其临床资料,评价CTA图像质量及动脉瘤特征,并与DSA结果对照。结果:320排动态容积CT脑血管成像动脉瘤显示优良率为94%。48例患者共检出颈内动脉颅内段动脉瘤53个,其中单发31例,多发17例;囊状动脉瘤45例,梭形动脉瘤3例。囊状动脉瘤中,最大径<5mm的小动脉瘤有44个,发生在交通段数目最多,为25个。结论:320排动态容积CT能够准确发现和评价颈内动脉颅内段动脉瘤,特别在颈内动脉颅内段动脉瘤的筛查中具有重要价值。 Objective:To evaluate the diagnostic value of 320-detector row CT in patients with intracranial internal carotid artery aneurysms. Methods:48 patients were diagnosed with of intracranial internal carotid artery aneurysms by 320-detector row CT angiography. The image of 48 patients were retrospectively analyzed combined with patient history and the results of digital subtraction angiography (I)SA). Image quality of CT angiography and position of aneurysms, number, and maximal dimension were recorded. Results:Fineness rate of 320-detector CTA image of intracranial internal carotid artery aneurysms was 94%. A total of 53 aneurysms were detected by 320-detector row CT angiography in 48 patients. Among them, 31 patients had single aneurysm, 17 patients had several aneurysms, 45 were saccular aneurysm, and 3 were fusiform aneury. In saccular aneurysms, the number of microaneurysm (〈5 mm) was 44, and location in posterior communicating artery section was 25. Conclusion: 320-detector row CT angiography can exactly discover and evaluate intracranial internal carotid artery aneurysms, especially have high value in screening intracranial internal carotid artery aneurysms.
出处 《医学影像学杂志》 2011年第8期1136-1139,共4页 Journal of Medical Imaging
关键词 320排CT 颅内动脉瘤 体层摄影术 X线计算机 血管造影术 数字减影 320-detector row CT Intracranial aneurysm Tomography, X-ray computed Angiography Digital sub-traction
  • 相关文献

参考文献5

二级参考文献47

共引文献51

同被引文献69

  • 1吕发金,罗天友,谢鹏,张志伟,沈云,牟君,廖静敏,方维东,陈垦.数字减影CTA图像质量影响因素探讨[J].重庆医科大学学报,2007,32(3):271-274. 被引量:59
  • 2吕发金,谢鹏,罗天友,张志伟,何怡红,孙晓川,牟君,方维东.数字减影CT血管成像在蛛网膜下腔出血诊断中的价值[J].中国医学影像技术,2007,23(1):45-48. 被引量:114
  • 3宁殿秀,李智勇,王克礼,苗延巍,伍建林,郎志谨,杜敏安.CT血管成像诊断脑动脉瘤的漏诊原因分析[J].放射学实践,2007,22(4):365-367. 被引量:17
  • 4Van Gijn J, Kerr RS, Rinkel GL. Subarachnioid haemorrhage. Lancet ,2007,369 (9558) :306-318.
  • 5Van Gelder JM. Computed tomographic angiography for detecting cerebral aneurysms: implications of aneurysms size distribution for the sensitivity, specificity and likelihood ratios. Neurosurgery, 2003, 53(3 ) :597-605.
  • 6White PM, Teasdale EM, Easton V, et al. Intraeranial aneurysnl : CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. Radiology, 2001,219 ( 3 ) : 739 - 749.
  • 7Lubicz B, Levivier M, Francois O, et al. Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms, interobserver and intertechnique reproducibility. AJNR Am J Neuroradiol,2007,28(10) : 1949-1955.
  • 8Yoon DY, Lim KJ, Choi CS, et al. Detection and characterization of intracranial aneurysms with 16-channel muhidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. AJNR Am J Neuroradiol,2007, 28 ( 1 ) :60457.
  • 9Hiratsuka Y, Miki H, Kiriyama 1, et al. Diagnosis of unruptured intraeranial Aneurysms: 3T MR angiography versus 64-channel multi-detector row CT angiography. Magn Reson Med Sci, 2008, 7(4) :169-178.
  • 10Luo Z, Wang D, Sun X, et al. Comparrison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT wth conventional CT angiography for diagnosis of intracranial aneurysms. Eur J Radiol,2012,81 ( 1 ) : 118-122.

引证文献9

二级引证文献64

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部