提出将空气-水作为热泵型空调器的复合热源。根据当前的研究状况,初步设计空气-水复合热源热泵型空调器,利用热力学原理分析该空调器的工作循环和特点,结果表明该空调器的制冷性能高于空气源热泵空调器,制热和室外换热器结霜状况得到一定改善。
It is proposed that the air-water multiple heat sources could be the heat source of heat pump air conditioner.Based on the current study condition,the heat pump air conditioner which has a air/family waste water multiple heat source is preliminary designed.The working cycle and characteristics of the air conditioner are analyzed by using the thermodynamic principle.The results show that the refrigeration performance of the heat pump air conditioner is better than that of air source heat pump air conditioner,the heating performance and the situation which the outdoor heat exchanger frosts are improved.
出处
《制冷与空调》
2012年第3期15-18,45,共5页
Refrigeration and Air-Conditioning
基金
桂林航天工业学院科研基金项目(X10Z005)
关键词
热泵
复合热源
节能
空调器
heat pump
multiple heat sources
energy conservation
air conditioner