期刊文献+

盐酸多西环素含量测定方法的比较 被引量:2

Comparison of Determination Methods of Doxycycline Hydrochloride Content
下载PDF
导出
摘要 目的:比较2种测量盐酸多西环素含量方法。方法:紫外分光光度法与高效液相色谱法。结果:紫外分光光度法测盐酸多西环素,在0.002~0.028 mg/mL范围内线性关系良好(r=0.9999),添加回收率为99.12%(n=5,RSD=1.79%);高效液相色谱法测盐酸多西环素,在0.005~0.180 mg/mL范围内线性关系良好(r=0.9999),添加回收率为99.90%(n=5,RSD=1.76%)。结论:紫外分光光度法操作方便快捷,高效液相色谱法更为可靠。 Objective: The research aimed to compare two different determination methods of doxycycline hydrochloride content. Method: The ultraviolet spectrophotometry method and HPLC method were used to determine doxycycline hydrochloride content. Result: The standard curve of ultraviolet spectrophotometry method showed a good linear relationship from 0.002 mg/mL to 2.8 mg/mL and the average recovery was 99.12 % (n=5, RSD=1.79 %).The standard curve of HPLC method showed a good linear relationship from 0.005 mg/mL to 0.180 mg/mL and the average recovery was 99.90 % (n=5, RSD= 1.76 %). Conclusion: The ultraviolet spectrophotometry method was more convenienct, the HPLC method was more reliable.
出处 《广东化工》 CAS 2012年第7期189-190,188,共3页 Guangdong Chemical Industry
关键词 盐酸多西环素 紫外分光光度法 高效液相色谱法 doxycycline hydrochloride: ultraviolet spectrophotometry: HPLC