期刊文献+

中子氧活化流量测试仪实流校准 被引量:1

Actual flow calibration of flow-meter for neutron oxygen activation
下载PDF
导出
摘要 井下脉冲中子氧活化类流量测试仪是生产测井过程中进行真实井况复现的专用测井仪器,目前国内外尚无可靠、准确、安全的校准方法。为此,采用了油气水流量综合检定装置与地下模拟实验井衔接的方法解决此类测井仪实流标定问题,同时可进行油田生产测试常规井下流量测试仪器的校准,并在应用中不断改进完善。应用此方法已对200多套井下流量含水测试仪器及氧活化类流量测井仪器实施了校准,实验表明该方法安全、可靠、有效。 Underground pulse neutron oxygen activation flow measurement is specific logging equipment for actual well condition repeatability and reproducibility during production logging procedure. There is no as yet reliable, accuracy and safety calibration methods at home and aboard at present. According to this situation, adopting oil-gas-water flow comprehensive investigate equipment combining with underground stimulation well to solve the actual flow calibration of this logging wells. Meanwhile, this method could conduct the calibration of underground flow testing equipment for conventional production measurement in oilfield, and be improved continuously during the application. At present, More than 200 sets of underground flow water-bearing test equipment and oxygen activation flow logging equipment were calibrated by this method, and the results prove that the method is safe, reliable and effective.
出处 《石油钻采工艺》 CAS CSCD 北大核心 2012年第4期104-106,共3页 Oil Drilling & Production Technology
关键词 氧活化测井 地下模拟井 辐射安全防护 氧活化测试仪实流校准 oxygen activation logging underground stimulation well safety for protection against radiation actual flow calibra-tion of flow-meter for oxygen activation
  • 相关文献

参考文献3

  • 1GB18871-2002.电离辐射防护与辐射源安全基本标准[S].[S].,..
  • 2Q/SYHB0096--2010.氧活化流量测试仪校准规程[S].
  • 3SY/T5362--1995.生产测井油气水流量模拟实验装置[s].

共引文献441

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部