期刊文献+

Design of OFF/ON fluorescent thiol probes based on coumarin fluorophore 被引量:2

Design of OFF/ON fluorescent thiol probes based on coumarin fluorophore
原文传递
导出
摘要 This paper presents a series of first- and second-generation click-modified coumarin-based fluorescent probes for thiols. These molecules demonstrate high turn-on fluorescent response and good selectivity towards aromatic thiols over other relevant reac- tive sulfur species, reactive oxygen species and common nucleophiles. Moreover, probe la can detect thiols in the reduced rabbit plasma sample. Therefore, this approach provides a particularly impressive tool for detecting thiol in biological systems. This paper presents a series of first-and second-generation click-modified coumarin-based fluorescent probes for thiols.These molecules demonstrate high turn-on fluorescent response and good selectivity towards aromatic thiols over other relevant reactive sulfur species,reactive oxygen species and common nucleophiles.Moreover,probe 1a can detect thiols in the reduced rabbit plasma sample.Therefore,this approach provides a particularly impressive tool for detecting thiol in biological systems.
出处 《Science China Chemistry》 SCIE EI CAS 2012年第9期1776-1780,共5页 中国科学(化学英文版)
基金 financed by grants from Shandong Natural Science Foundation (JQ201019) Independent Innovation Foundation of Shandong University,IIFSDU (2010JQ005)
关键词 COUMARIN fluorescent probe aliphatic thiols THIOPHENOLS 荧光探针 香豆素类 探针设计 巯基 OFF 基础 荧光反应 亲核试剂
  • 相关文献

参考文献24

  • 1Shahrokhian S. Lead phthalocyanine as a selective carrier for preparation of a cysteine-selective electrode. Anal Chem, 2001,73: 5972-5978.
  • 2Townsend DM, Tew KD, Tapiero H. The importance of glutathione in human disease. Biomed Pharmacother, 2003,57: 145-155.
  • 3Njalsson R, Norgren S. Physiological and pathological aspects of GSH metabolism. Acta Paediatr, 2005,94: 132-137.
  • 4Amrolia P, Sullivan SG, Stern A, Munday R. Toxicity of aromatic thiols in the human red blood cell. J Appl Toxicol, 1989, 9: 113-118.
  • 5Munday R. Toxicity of aromatic disulphides. I. Generation of superoxide radical and hydrogen peroxide by aromatic disulphides in vitro. J Appl Toxicol, 1985, 5: 402-408.
  • 6Fairchild EJ, Stokinger HE. Toxicologic studies on organic sulfurcompounds. I. Acute toxicity of some aliphatic and aromatic thiols(mercaptans). Am Ind Hyg /4.v.sy>c 7, 1958, 19: 171-189.
  • 7Xu Z, Chen X,Kim HN, Yoon J. Sensors for the optical detection ofcyanide ion. Chem Soc Rev, 2010, 39: 127-137.
  • 8Cho DG, Sessler JL. Modern reaction-based indicator systems. ChemSoc Rev, 2009, 38: 1647-1662.
  • 9Blom H, Kastrup L, Eggeling C. Fluorescence fluctuation spectroscopy in reduced detection volumes. Curr Pharm Biotechnol, 2006,7: 51-66.
  • 10Kim SA, Schwille P. Intracellular applications of fluorescence correlation spectroscopy: prospects for neuroscience. Curr Opin NeurobioU2003, 13: 583-590.

同被引文献20

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部