摘要
本文基于试验方法研究了叶轮结构形式和性能相差均较大的两台离心通风机串联工作时的性能。结果表明,当两台风机均正常工作时,它们在串联中的相对位置不影响串联试验性能,所得压力基本是两台风机单独工作时的压力之和。
In this paper, the performances of the two centrifugal fans in series are studied and in which there are larger differences between the structure of their impellers and performances base on experimental result. The test result indicates that the obtained pressure is the basic sum of the two fans of working individually when they are in normal operation and their relatively location in series has no influence on the experimental result.
出处
《风机技术》
2012年第4期32-33,45,共3页
Chinese Journal of Turbomachinery
关键词
离心通风机
串联
数据采集
Centrifugal fan
in series
data acquisition