详细描述并总结了国产硼表需进行的主要参数测试、标定技术等试验研究内容,通过采用等量置换法进行硼表的标定,优化了标定技术。同时亦证明了等量置换法标定技术是一种快速、便捷、可靠的标定技术,为核电站硼表的测试与标定提供了一种有效的方法。
It primarily describes and summarizes the main parameters of domestic boron meter test,the calibration technology test research etc.Equivalenting replacement method for the calibration of boron meter,and to optimize the calibration technique.At the same time,this method has also proved that the same amount of displacement method calibration technique is a fast,convenient and reliable calibration technique which provides an effective method for testing and calibration of the nuclear power plant boron table.