变压器油基础油烃组成与其脉冲击穿电压和电阻率的关联性研究 被引量:5

Correlations between the Composition of Base Oil Hydrocarbon and Its Impulse Breakdown Voltage and Resistivity in Transformer Oil
下载PDF
导出
摘要 针对脉冲功率装置的Marx脉冲发生器绝缘用油的特点,开展了变压器油基础组成与其电阻率和脉冲击穿电压大小的关联性研究。结果表明:在直流电场下,温度与电阻率的大小成反比关系,变压器油的芳烃含量是影响其电阻率的关键因素。在正负性脉冲电场下,不同芳烃含量的变压器油表现出极大的差异性,在高压负脉冲电场下,变压器油的芳烃含量是影响其脉冲击穿电压的主要因素,芳烃含量的高低与负脉冲击穿电压的大小成反比关系。 In view of the characteristics of insulating oil used in Marx pulse generator of pulsed power facilities,the correlations between the composition of base oil hydrocarbon and resistivity,impulse breakdown voltage in transformer oil were investigated.The results indicate that under DC electric field,resistivity is inversely proportional to temperature.The aromatic content of transformer oil is a key factor influencing the resistivity.The transformer oil with different aromatic content displays enormous difference in positive or negative impulse electric field.Under high voltage negative impulse electric field,the aromatic content is a main factor influencing the impulse breakdown voltage,and the aromatic content is inversely proportional to the negative impulse breakdown voltage.
出处 《绝缘材料》 CAS 北大核心 2012年第4期49-52,共4页 Insulating Materials
关键词 变压器油 Marx脉冲发生器 基础油组成 脉冲击穿电压 电阻率 transformer oil; Marx pulse generator; composition of base oil; impulse breakdown voltage; resistivity
  • 相关文献

参考文献10

  • 1夏明鹤,李洪涛,姚斌,丰树平,王玉娟,孟维涛,卫兵,何安,计策,田青,傅贞,丁胜,任靖,卿艳玲,谢卫平.脉冲功率装置的脉冲形成单元研究[J].强激光与粒子束,2007,19(9):1567-1570. 被引量:6
  • 2丰树平,李洪涛,谢卫平,邓建军,夏明鹤,计策,王勐,关永超,何安.Z箍缩初级实验平台模块样机[J].强激光与粒子束,2009,21(3):463-467. 被引量:29
  • 3GB/T5654-2007,液体绝缘材料相对电容率、介质损耗因数和直流电阻率的测量[s].
  • 4ASTM D924-08,Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Con- stant) of Electrical Insulating Liquids[S].
  • 5DL/T421-2009,电力用油体积电阻率测定法[s].
  • 6ASTM Dl169-11,Standard Test Method for Specific Resis- tance (Resistivity) of Electrical Insulating Liquids[S].
  • 7GB/T21222-2007,绝缘液体雷电冲击击穿电康测定方法[S].
  • 8DL418-91,绝缘液体雷电冲击击穿电压测定法[S].
  • 9IEC 60897-1987,Methods for the Determination of the Light- ning Impulse Breakdown Voltage of Insulating Liquids[S].
  • 10ASTM D3300-2006,Standard Test Method for Dielectric Breakdown Voltage of Insulating OiLs of Petroleum Origin Under Impulse Conditions[S].

二级参考文献8

  • 1邱爱慈.脉冲X射线模拟源技术的发展[J].中国工程科学,2000,2(9):24-28. 被引量:32
  • 2李洪涛,王玉娟,夏明鹤,关永超,傅贞,丁胜,任靖,孟维涛,戴英敏,韩文辉,丁伯南,丰树平,谢卫平,邓建军.高功率Z-pinch装置5MV主开关及开关区设计[J].强激光与粒子束,2006,18(3):459-462. 被引量:9
  • 3夏明鹤,王勐,王玉娟,计策,李洪涛,关永超,杨自祥,谢卫平,丰树平.4MV同轴-三平板型水介质自击穿开关设计[J].强激光与粒子束,2006,18(3):496-500. 被引量:9
  • 4Woodworth J R, Lehr J, Miller P A, et al. Optical diagnostics of 4-MV water switches in the Z-20 test facility[C]//14^th IEEE International Pulsed Power Conference. 2003 : 167-170.
  • 5Rosenthat S E, Pointon T D. Investigating the electromagnetic structure of the coax-to-triplate transition for the pulse-compression section of the Z-accelerator[C]//14^th IEEE International Pulsed Power Conference. 2003:626-629.
  • 6Struve K W, Corley J P, Johnson D L. Design options for a pulsed power upgrade of the Z accelerator[C]//13^th IEEE International Pulsed Power Conference. 2001:100-103.
  • 7Harjes C, Elizondo J. Circuit modeling for ZR[C]//14^th IEEE International Pulsed Power Conference. 2003:917-920.
  • 8Martin T H, Guenther A H, Kristiansen M J C. Martin on pulsed power[M]. New York:Plenum Press, 1996.

共引文献33

同被引文献55

引证文献5

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部