期刊文献+

Waters ACQUITY UPC^2仪器结构和性能特点 被引量:34

The characters of Waters ACQUITY UPC^2 system
下载PDF
导出
摘要 Waters超高效合相色谱(Ultra Performance Convergence Chromatography,UPC2)技术集合SFC和UPLCTM的技术优点。泵系统的传输性能精准(精度0.001mL/min);样品室温控4~40℃,应用nano阀技术的进样器可在0.1~50μL内调控,进样线性>0.999、进样交叉污染<0.005%;色谱柱管理器可容纳并自动切换6根色谱柱,色谱柱具有eCordTM、主动预加热器功能(温控精度±0.1℃);可连接PDA、ELSD以及质谱等检测器。结合亚2μm颗粒填料技术,UPC2系统在以下应用方面分析结果优异:手性化合物、脂质、异构体、天然产物提取物等复杂体系,正相HPLC取代技术,GC、反相HPLC的正交、互补技术。 Waters Ultra Performance Chromatography(UPC2)is a novel chromatography technology,which integrates the advantages of SFC and Waters UPLC^TM technologies.BSM pump delivers much more precise solvent(0.001mL/min increments);Sample Manager controls the sample temperature from 4.0-40.0℃,and the injector with the advanced nano-valve technology,which injection volume ranges from 0.1-50.0μL,the injection linearity is more than 0.999 coefficient of deviation,and the sample carryover is less than 0.005%.Column Manager with the capacity of 6 columns,which provides automatic switching,active pre-heating,and eCordTM technology for column tracking;PDA,ELSD and MS detectors can be used in the system.Combining the sub-2 μm particle technology,UPC^2 makes a great progress in the following applications: chiral compounds,isomers,lipids,the complex TCM extractions,the substituent for normal HPLC,the orthogonality and complementary to GC and RPLC.
出处 《现代仪器》 2012年第5期45-48,共4页 Modern Instruments
关键词 超高效合相色谱 色谱分析 分离新技术 UPC^2 Chromatographic ananlysis, New seperation technology
  • 相关文献

参考文献12

  • 1刘虎威.气相色谱方法及应用.第二版,北京:化学丁业出版社,2010.
  • 2许行义.气相色谱在环境检测中的应用.第一版,北京:化学工业出版社,2012.
  • 3于世林.高效液相色谱方法及应用.第二版,北京:化学丁业出版社.2010.
  • 4盛龙生,汤坚.液相色谱质谱联用技术在食品和药品分析中的应用.第一版,北京:化学工业出版社,2008.
  • 5韩布兴,等.超临界流体科学和技术.第一版,北京:中国石化出版社,2005.
  • 6Larry T. Taylor Supercritical fluid chromatography for the 21' century[J]. Journal of Supercritical Fluids, 2009,47:566-573.
  • 7Olle Gyllenhaal, etc, Potential of packed column supercritical fluid chromatography for the separation of metoprolol from closely related compounds[J]. Journal of Chromatography A, 1999,839:141-148.
  • 8Dennis R. Gere, etc. Supercritical fluid chromatograph with small particle diameter packed columns[J]. Analytical Chemistry,1982, 54(4):737-740.
  • 9T.A. Berger. The effect of adsorbed mobile phase components on the retention mechanism, Efficiency, and peak distortion in supercritical fluid chromatography [J]. Chromatographia. 1993, 37:11/12.
  • 10Mu Zou Wang, etc, Achiral and chiral analysis of camazepam and metabolites by packed-column supercritical fluid chromatography[J]. Journal of Chromatography B. 1995,665:139-146.