期刊文献+

锁定接骨板治疗四肢长管状骨骨折后的疗效 被引量:2

Curative effect of locking proximal humeral plate in treatment of Limbs long tubalar bone fracture
下载PDF
导出
摘要 目的探讨使用锁定接骨板治疗四肢长管状骨骨折的效果。方法对该院收治的四肢长管状骨骨折81例患者随机分为两组。对照组给予外固定架治疗,实验组给予锁定接骨板治疗,比较两组患者的治疗效果。结果实验组患者的出血量和手术时间高于对照组患者,P<0.05;实验组患者愈合率高于对照组患者,固定松动等低于对照组患者,P<0.05。结论使用锁定接骨板治疗四肢长管状骨骨折具有较好的效果,医生要根据患者的实际情况选择合适的治疗方法,使骨折愈合更好。 Objective To investigate the effect of locking plate treatment of limb long bone fractures.Methods 81 patients limb long bone fractures were randomly divided into two groups.The control group was given the external fixator,the experimental group was given a locking plate treatment,the treatment effect of the two groups were compared.Results The experimental group of patients with blood loss and operative time was higher in patients,P0.05;experimental group patients healing rate was higher in patients with loosening lower than control group patients(P0.05).Conclusion Use the locking plate treatment of limb long bone fractures with good results,the doctor should select the appropriate treatment according to the actual situation of the patients,the fractures were healing better.
作者 沈峰
出处 《中外医疗》 2012年第25期80-80,82,共2页 China & Foreign Medical Treatment
关键词 锁定接骨板 四肢长管状骨 骨折 外固定架 Locking plate The long tubular bones of the limbs Fracture External fixator
  • 相关文献

参考文献5

二级参考文献24

  • 1Perren SM. Backgrounds of the technology of internal fixators [ J ].Injury, 2003,34 ( S2 ) : 1 - 3.
  • 2Chapman JR, Harrington RM, Lee KM. Factors affecting the pullout strength of cancellous bone screws [ J 1. J Biomech Eng,1996,118(3) :391 -398.
  • 3Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws[ J]. J Orthop Trauma,2004, 18 (8) :488 -493.
  • 4Ring D, Kloen P, Kadzielski J, et al. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus [ J ].Clin Orthop Relat Res,2004,425 (1):50- 54.
  • 5Ring D, Percy BH, Jupiter JB. The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients [ J ]. J Bone Joint Surg ( Am), 1999,81 (2) : 177 - 190.
  • 6Zhao YF, Li QH, Gu ZC, et al. The biomeehanies of point contact dynamic compression plate and its effects on bone perfusion [ J ]. Chin J Traumatol, 2006,9 (3) : 161 - 167.
  • 7O'Beirne J, O Connell R J, White JM, et al. Fractures of the femur treated by femoral plating using the anterolateral approach [J]. Injury, 1986,17 (6): 387 - 390.
  • 8Bucholz RW,Jones A. Fractures of the shaft of the femur [J].J Bone Joint Surg (Am), 1991,73 ( 10): 1561 - 1566.
  • 9Xu X,Zhang X, Liu J, et al. Stress analysis after femoral shaft osteotomy fixed by various plates with different rigid- ities in simulation test [J]. Chin Med J, 1993,106 (2): 127 - 131.
  • 10Ellis T, Bourgeault CA, Kyle RF. Screw position affects dynamic compression plate strain in an in vitro fracture model[ J ]. J Orthopaedic Trauma, 2001,15 ( 5 ) : 333 - 337.

共引文献25

同被引文献10

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部