对江苏利港电厂1号发电机(350 MW)集电环环火事故原因进行了分析,并对故障的修复处理过程作详细论述,针对本次故障处理情况并结合该厂发电机集电环运行经验,探讨了集电环稳定运行的方法手段。
This paper analyzed the cause of ring fire accident of the generator No 1 collecting ring in Ligang Power Plant, and discussed in detail the repair process of the failure, according to the fault handling and combined with plant's generator collecting ring operating experience, investigated the methods and means for the stable operation of the collecting ring.
出处
《华北电力技术》
CAS
2012年第10期47-51,共5页
North China Electric Power
关键词
发电机
集电环
环火
氧化膜
generator
collecting ring
ring fire