期刊文献+

最小二乘法的未知控制点检测

Detection of the invisible control points by least square method
下载PDF
导出
摘要 背景:数字减影血管造影系统使用X射线影像增强器作为图像检测器,获取的投影图像与真实图像之间存在几何失真。目的:为实现脑血管的三维重建,对数字减影血管造影图像的几何失真进行校正。方法:基于数学形态学检测可视控制点,在此基础上采用最小二乘法曲线拟合进行非可视控制点检测,利用获取的672个控制点对原始图像进行非线性局部校正。结果与结论:实验结果表明在边缘校正的结果较好,圆弧区域基本不失真。使用最小二乘法曲线拟合得到的控制点坐标准确性高,图像校正结果好,可用于脑血管数字减影血管造影图像的校正,为后续的三维重建提供保证。 Abstract BACKGROUND: Digital subtraction angiography system uses the X-ray image intensifier as an image detector and the geometric distortion exists between the real image and the obtained image. OBJECTIVE:To correct the geometric distortion of digital subtraction angiography image in order to achieve three-dimensional reconstruction of cerebral blood vessels. METHODS: Based on mathematical morphology to detect visual control point, a method of least squares was used in this article to process the images in order to gain the coordinates of the invisible control points. The obtained 672 control points were used to do the nonlinear partial correction on the original image. RESULTS AND CONCLUSION: Experiment results showed that there were better results in the edge correction without distortion in arc region basically. The method of least squares curve achieved high accuracy control points and good image correction results, it could be used in distortion correction of digital subtraction angiography images and provided guarantee for a subsequent three-dimensional reconstruction.
出处 《中国组织工程研究》 CAS CSCD 2012年第39期7307-7311,共5页 Chinese Journal of Tissue Engineering Research
基金 国家自然科学基金资助项目(72054) 河南省教育科学"十一五"规划课题(2009-JKGHAG-614)~~
  • 相关文献

参考文献22

  • 1王金龙,凌锋,李慎茂,宋庆斌,黄居义,王玉林,吴婷夏.旋转DSA及三维重建技术在颈动脉狭窄介入治疗中的应用[J].中国医学影像技术,2005,21(1):112-114. 被引量:18
  • 2Yan S,Nie S,Zheng B. Improving accuracy of XRII image distortion correction using a new hybrid image processing method:performance assessment[J].Medical Physics,2011,(11):5921-5932.
  • 3Yan S,Wang C,Ye M. A method based on moving least squares for XRII image distortion correction[J].Medical Physics,2007,(11):4194-4206.
  • 4Cerveri P,Forlani C,Borghese NA. Distortion correction for x-ray image intensifiers:local unwarping polynomials and RBF neural networks[J].Medical Physics,2002,(08):1759-1771.
  • 5Gronenschild E. Correction for geometric image distortion in the x-ray imaging chain:local technique versus global technique[J].Medical Physics,1999,(12):2602-2616.
  • 6Fantozzi S,Cappel o A,Leardini A. A global method based on thin-plate splines for correction of geometric distortion:an application to fluoroscopic images[J].Medical Physics,2003,(02):124-131.
  • 7Gutiérrez LF,Ozturk C,McVeigh ER. A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system[J].Medical Physics,2008,(03):997-1007.
  • 8黄惠芳,胡广书.脑血管DSA三维重建技术[J].北京生物医学工程,2008,27(2):215-218. 被引量:2
  • 9马炘,吴剑煌,马仁辉.改进的血管三维建模算法[J].计算机辅助设计与图形学学报,2010,22(6):1050-1055. 被引量:7
  • 10S?derman M,Picard C,Ericson K. An algorithm for correction of distortion in stereotaxic digital subtraction angiography[J].Neuroradiology,1998,(05):277-282.

二级参考文献119

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部