期刊文献+

测定棕刚玉中氧化铝含量的影响因素

Influence Factors of Test for Aluminum Oxide Content in Brown Fused Alumina
下载PDF
导出
摘要 基于EDTA容量法测定棕刚玉中氧化铝含量,设计了控制试验的条件,探讨了影响试验结果的因素并分析其原因。结果表明:采用返滴定EDTA容量法测定氧化铝含量时,正确控制操作过程中试样熔融时间及试液pH值、反应时间和指示剂用量等因素,可提高分析结果的准确度和可信度。 Based on the EDTA volumetric method for test of aluminum oxide in brown fused alumina, the conditions to control experiment were designed. The influence factors of the test results were discussed and their causes were analyzed. The results show that the fusing time of samples, the pH value and reaction time of test solution and the amount of indicator are controlled properly in test for alumina oxide content with back titration of EDTA volumetric method, which can improve the accuracy and reliability of analytical results.
出处 《铸造工程》 2012年第6期13-15,共3页 Foundry Engineering
关键词 棕刚玉 氧化铝含量 EDTA容量法 brown fused alumina aluminum oxide content EDTA volumetric method
  • 相关文献

参考文献9

二级参考文献25

  • 1严德明,吕明,杨闯,崔运成.铅—二甲酚橙—甲基紫三元络合物光度法测定痕量铅[J].吉林师范大学学报(自然科学版),2004,25(4):53-54. 被引量:6
  • 2李惠霞,张其颖,王浩月.新显色剂DBS-MSA测定痕量铅的分光光度法研究[J].华东师范大学学报(自然科学版),2005(4):110-112. 被引量:4
  • 3杭州大学化学系分析教研室.分析化学手册(第二分册化摹分析)[M].1986:621.
  • 4HOLZBECHER Z, DIVIS L, KRAL M, et al. Handbook of Organic Reagents in Inorganic Analysis(无机分析中的有机试剂手册)[M].中山大学,北京大学,南开大学译.北京:高等教育出版社,1984:436.
  • 5NAKAYAMA Hiroaki, TACHIYASHIKI Satoshi, ISHII Minoru. Preparation of high purity xylenol orange and isolation of a new metallochromic dye by cation exchange column chromatography on sp-sephadex [J]. Analytical Sciences, 1989, 5: 619-621.
  • 6YANG Tai-Lin. Xylenol orange tetrasodium salt/ TiO2 films for quantitative analysis of cobalt ion (Co^2+) and coordination of Zn^2+ to xylenol orange anion investigated by molecular dynamics simulation [D]. Taiwan:National Cheng Kung University, 2007-08-02. http ://etdncku. lib. ncku. edu. tw / ETD- db / ETD-browse /browse ? first_letter = Y .
  • 7ONISHI Hiroshi, ISHIWATARI Nasumi. Spectrophotometric determination of bismuth with xylenol orange[J]. Bulletin of the Chemical Society of Japan, 1960, 33(11): 1581-1584.
  • 8Chandra D Dwivedi, Arun K Dey. Photometric determination of trivalent gallium, indium and thallium with xylenol orange[J]. Mikrochimica Acta , 1968:708-711.
  • 9Kate Grudpan, Mayuree Utamong, Colln G laylor. Determination of zirconium with xylenol orange by flow injection spectrophotometry: application to eluates from technetium-99m generators [J]. Analytical Communications, 1998, 35:107 - 108.
  • 10KOMPANY-ZAREH M, MASSOUMI A, PEZESHK-ZADEH Sh. Simultaneous spectrophotometric determination of Fe and Ni with xytenol orange using principal component analysis and artificial neural networks in some industrial samples[J]. Talanta, 1999, 48: 283- 292.

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部