Ferroresonance at Open Phase Operating Conditions of Power Transformers
Ferroresonance at Open Phase Operating Conditions of Power Transformers
摘要
The reliability of electric supply to consumers is one of the most important factors that determine the requirements imposed on modem utility companies. This paper presents the results of investigation by computer software of the overvoltages resulting from a ferroresonance conditions in MV networks at open phase operating condition with and without connection to earth on source and load sides of distribution transformer. This overvoltage may reach 4.2 pu on one of the HV side of transformer unswitched phases. The results of the study show that ferroresonance overvoltage may be controlled by replacing fuses with circuit breakers on HV side to ensure switching-off all phases. Insertion of resistor or reactor in the neutral of source and loadsides of the transformer with 5% active load will help in suppressing overvoltages.
参考文献8
-
1L.P. Nieman, K.S. Demerchain, Theoritical Fundamentals of Electrotechnology, Energia Publishers, Moscow, 1967.
-
2AL. Shenkman, Transients of Electric Power Circuits Handbook, Springer, Netherlans, 2005.
-
3V. Velverde, AJ. Mazon, 1. Zamora, G. Buigues, Ferroresonance in voltage transformer: Analysis and simulation, Research Team of Project UE03!AO, University of the Basque Country, 2003.
-
4R.C. Dugan, Examples of ferroresonance in distribution systems, in: IEEE Power Engineering Society General Meeting, Toronto, 2003.
-
5R. Rudenberg, Transient Performance of Electrical Power Systems, Foreign Literature Publishers, Moscow, 1955. (in Russian).
-
6AS. Abdallah, M.A Ei-kady, Ferroresonancephenomenon in power transformers-Experimental assessment, JKAU: Eng. Sci. 16 (1) (2005) 71-82.
-
7A Nayer, AR. Babayeva, E.V. Dmitryev, AM.Hashirnov, I.R. Pivchik, Mathematical modelling of ferrresonance for investigation of ferroresonance currents, Journal of Electrical & Electronics Engineering 5 (2) (2005) 1373-1377.
-
8G. Buigues, 1. Zamora, V. Valverde, A.j. Mazon, U.S.Martin, Ferroresonance in three-phase power distribution transformers: Sources, consequences and prevention, in: 19th International Conference on Electricity Distribution, Vienna, May 21-24, 2007.
-
1艾永乐,尹红霞.电流源及其在电子电路中的应用研究[J].焦作工学院学报,1999,18(4):281-283. 被引量:2
-
2彭刚,张崇金.同步Buck电路在有源负载中的关键技术[J].电力电子技术,2013,47(4):84-86. 被引量:3
-
3徐炯.浅议带有源负载的小型三相同步中频发电机的设计和并联运行[J].中小型电机,2002,29(5):48-50.
-
4智能型全自动蓄电池充放电装置[J].技术与市场,2008,15(10):19-19.
-
5智能型全自动蓄电池充放电装置[J].科技开发动态,2005(10):54-54.
-
6惠萌,刘崇新.Effect of power frequency excitation character on ferroresonance in neutral-grounded system[J].Chinese Physics B,2010,19(12):109-114. 被引量:2
-
7蒋玉萍.线性功率MOSFET分析及应用[J].电源世界,2008(4):66-68. 被引量:3
-
8倪海东,蒋玉萍.线性功率MOSFET分析及应用[J].电源世界,2005(6):59-61.
-
9Joel Setton.低至2V以下工作的精密有源负载[J].电子设计技术 EDN CHINA,2005,12(11):97-97.
-
10裴学元,浦秋棣.ECCT-1型精密钳形电流互感器[J].电测与仪表,1999,36(7):13-16. 被引量:2