期刊文献+

基于ARM的肝储备功能检测仪的设计与实现

Design and realization of liver reserve function detector based on ARM
下载PDF
导出
摘要 肝脏储备功能的评估是安全开展肝切除手术的基础和技术保证,是肝脏外科的核心问题之一。将微型机和光电传感技术运用于生物医学工程领域,结合脉搏染料密度分光光度法原理,设计了一种三波长肝储备功能检测仪,能有效评估肝脏储备能力。用该设备对患者进行了临床实验,实验结果显示:该检测仪信号稳定可靠,具有临床实用价值。 The assessment of liver reserve function is the foundation and technical assurance in liver resection operation safety,it is one of the core problems in hepatic surgery.The miniature machine and photoelectric sensor technology are applied in the field of biomedical engineering,combined with pulse dye density spectrophotometry method theory,a three-wave-length liver reserve function detector is designed,which can effectively evaluate the liver reserve ability.Using the device on patients in a clinical experiment,the experimental results show that the detector signal is stable and reliable,it has clinical practical value.
出处 《传感器与微系统》 CSCD 北大核心 2012年第11期108-110,共3页 Transducer and Microsystem Technologies
基金 卫生部专项课题资助项目(202152965) 中央高校基本科研业务费专项基金资助项目(201120202020006) 武汉市"3551人才计划"资助项目(2010-210)
关键词 肝储备功能 ARM WINCE 吲哚青绿 liver reserve function ARM WinCE ICG
  • 相关文献

参考文献6

  • 1Nihon Kohden Corporation. Pulse oximeter and pulse oximeter:US, 20090318787A1 [ P]. 2009-12-24.
  • 2lijima T,Aoyagi T, Iwao Y, et al. Cardiac output and circulationg blood volum eanalysis by pulse dye-densitometry [ J ]. Journal of Clinical Monitoring, 1997,13:81 -89.
  • 3Aoyagi T. Pulse oximetry : Its invention, theory, and future[ J ]. J Anesth ,2003,17:259 -266.
  • 4Luo Q, Nioka S, Chanee B. Funetional near-infrared imager,in opti- cal tomography and spectroscopy of tissue :Theory,instrumentatlon, model,and human studies II[J]. SPIE. 1997,2979:84-93.
  • 5孙涛,张宏建.基于一阶差分的粗差剔除方法[J].仪器仪表学报,2002,23(2):197-199. 被引量:14
  • 6郭静玉,何琳,景爱华.阈值法在脉搏信号特征提取中的应用[J].河南科技大学学报(医学版),2011,29(1):1-3. 被引量:7