期刊文献+

体外预应力混凝土梁的预应力筋应力增量研究 被引量:2

STUDY ON STRESS INCREMENT OF TENDON FOR EXTERNALLY PRESSTRESSED CONCRETE BEAMS
原文传递
导出
摘要 为了推广体外预应力技术在混凝土结构,特别是在低强度混凝土梁加固中的应用,对12根体外预应力加固混凝土梁展开静载试验。结合模型梁抗弯性能的试验研究,重点分析预应力筋应力增量对抗弯承载力计算的影响。研究成果表明:预应力筋应力增量是影响体外预应力混凝土梁抗弯承载力计算精度的主要因素,试验结果表明,JGJ/T 92—2004《无粘结预应力混凝土结构技术规程》中关于体外预应力应力增量值100 MPa明显偏低,建议修订为170 MPa。 To promote the technology of externally prestressed concrete structures, especially in the reinforcement of low-strength concrete beams. Twelve externally prestressed concrete beams were tested with static load. Combining with the study of bending performance of model beam, it was analyzed the affect of the stress increment of tendon on flexural capacity. Test results show that the stress increment is the important factor influencing accuracy of bending capacity of externally prestressed concrete beams, and is significantly lower, and the value of the stress increment specified as 100 MPa in JGJ 92 it is suggested that this value should be 170 MPa.
出处 《工业建筑》 CSCD 北大核心 2012年第11期136-139,共4页 Industrial Construction
关键词 体外预应力 静载试验 承载力分析 externally prestressed static load test analysis of bearing capacity
  • 相关文献

参考文献9

二级参考文献15

  • 1朱伯龙 董振祥.钢筋混凝土非线性分析[M].上海:同济大学出版社,1984..
  • 2林同炎 HED H.BURNS.预应力混凝土结构设计(第三版)[M].北京:中国铁道出版社,1983..
  • 3牛斌.体外预应力混凝土梁抗弯强度及变形性能(硕士学位论文)[M].北京:铁道部科学研究院,1992..
  • 4杜拱辰.现代预应力混凝土结构[M].北京:中国建筑工业出版社,1986.199-231.
  • 5王宗林.体外承应力混凝土桥梁结构极限状态分析[M].哈尔滨:哈尔滨工业大学,2001.9-26.
  • 6Zhang Zuohan,The Symposium on Post-Tensioned Concrete Structures,1993年
  • 7牛斌,硕士学位论文,1992年
  • 8朱伯龙,钢筋混凝土非线性分析,1984年
  • 9林同炎,预应力混凝土结构设计(第3版),1983年
  • 10王有志.预应力混凝土结构[M].北京:中国水利水电出版社,1998..

共引文献1507

同被引文献10

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部