期刊文献+

聚醚醚酮棒椎弓根内固定系统在腰椎退行性疾病治疗中的应用 被引量:7

Pedical dynamic internal fixation using polyetheretherketone rods for the treatment of degenerative lumbardiseases
原文传递
导出
摘要 目的分析聚醚醚酮棒(PEEK棒)椎弓根螺钉内固定系统在治疗腰椎退行性疾病中的应用可行性。方法对比分析分别采用PEEK棒内固定(P组,13例)及传统钛棒固定(T组,15例)后路椎管减压椎体间融合治疗腰椎退行性病变的两组患者的资料,通过日本骨科学会(JOA)评分评价临床疗效,并比较两组间手术时间、术中输血量、以及末次随访时椎间融合率及相关并发症。结果所有患者术后均经过6个月以上的随访。P组术前JOA评分10.53±1.90,术后为24.1±1.93,手术前后JOA评分改善率为(73.7±9.33)%;T组术前JOA评分为9.33±1.95,术后为23.7±1.83,手术前后JOA评分改善率为(73.3±9.15)%,差异无统计学意义(P=0.891)。植骨融合情况:P组9例为1级,4例为2级;T组15例中5例为1级,7例为2级,3例为3级,差异有统计学意义(P=0.036)。结论PEEK棒椎弓根螺钉内固定与坚强内固定治疗腰椎退行性疾病相比,短期可取得相同的疗效。PEEK棒组的骨融合率要高于传统钛棒组。PEEK棒治疗腰椎退行性疾病的长期临床效果尚有待进一步观察。 Objective To investigate the feasibility of pedical dynamic internal fixation by using polyelheretherketone (PEEK) rods for the treatment of degenerative lumbar diseases. Methods Effects of treatment using PEEK rods (group P, n=13) and conventional titanium rod fixation (group T, n=15) , namely the posterior lumbar vertebral fusion, on patients with degenerative lumbar diseases were compared. The clinical efficacy was assessed based on Japanese Orthopaedic Association (JOA) scoring. The duration of operation, volume of blood transfusion during surgery, bone fusion rate at the final visit and relevant complications were also compared. Results All patients were followed-up for a minimum of 6 months. Group P had mean JOA score of 10.53+ 1.90 and 24.1 + 1.93 pre-operatively and post-operatively, and these figures were 9.33±1.95 and 23.7± 1.83 in group T, respectively. Improvement rates of groups P and T were (73.7±9.33)% and (73.3_+9.15)%, respectively (P=0.891). Group P differed significantly (P=0.036) in terms of bone fusion rate (9 for grade 1 and 4 for grade 2) as compared with that of group T (5 for grade 1, 7 for grade 2 and 3 for grade 3). Conclusions Pedical dynamic internal fixation using PEEK rods has some result of titanium rod fixation for short-term treatment of degenerative lumbar diseases. Although PEEK rod treatments has higher fusion rate, long-term efficacy remains to be further studied.
出处 《中华生物医学工程杂志》 CAS 2012年第5期395-398,共4页 Chinese Journal of Biomedical Engineering
关键词 腰椎 内固定器 聚醚醚酮棒 Lumbar vertebrae Internal fixators Titanium Poly(ether-ether-ketone) rods
  • 相关文献

参考文献5

  • 1Ponnappan RK, Serhan H, Zarda B, et al. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation. Spine J, 2009, 9 : 263-267.
  • 2ho Z, Matsuyama Y, Sakai Y, et al. Bone union rate with autologous iliac bone versus local bone graft in posterior lumbar interbody fusion. Spine(Phila Pa 1976), 2010, 35 :E1101-1105.
  • 3Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials, 2007, 28:4845-4869.
  • 4Ahn YH, Chen WM, Lee KY, et al. Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices. Biomed Mater, 2008, 3: 044101.
  • 5Highsmith JM, Tumialan LM, Rodts GE Jr. Flexible rods and the case for dynamic stabilization. Neurosurg Focus, 2007,15 : E11.

同被引文献44

  • 1郑燕平,刘新宇,贾龙,王延国,黎君彦.腰椎后路椎间融合术后椎间融合的X线片及三维CT评价[J].中华骨科杂志,2009,29(12):1104-1108. 被引量:22
  • 2Kanayama M,Togawa D,Hashimoto T,et al.Motion-preserving surgery can prevent early break down of adjacent segments:comparison of posterior dynamic stabilization with spinal fusion[J].Spinal Disord Tech,2009,22(7):463-467.
  • 3Park P,Garton HJ,Gala VC,et al.Adjacent segment disease after lumbar or lumbosacral fusion:revie of the literature.Spine,2004,29(17):1938-1944.
  • 4Brantigan JW,Steffee AD,Lewis ML,et al.Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system:two-year results from a Food and Drug Administration investigational device exemption clinical trial[J].Spine,2000,25(11):1437-1446.
  • 5Kurtz SM,Devine JN.PEEK biomaterials in trauma,orthopedic,and spinal implants[J].Biomaterials,2007,28(32):4845-4869.
  • 6Ponnappan RK,Serhan H,Zarda B,et al.Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation[J].Spine,2009,9(3):263-267.
  • 7Mavrogenis AF,Vottis C,Triantafyllopoulos G,et al.PEEK rod systems for the spine[J].Eur J Orthop Surg Traumatol.2014,24(Suppl 1):S111-116.
  • 8Aota Y,Kumano K,Hirabayashi S.Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders[J].J Spinal Disord,1995,8(6):464-473.
  • 9Etebar S,Cahill DW.Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability[J].Neurosurg,1999,90(2 Suppl):163-169.
  • 10Athanasakopoulos M,Mavrogenis AF,Triantafyllopoulos G,et al.Posterior spinal fusion using pedicle screws[J].Orthopedics,2013,36(7):e951-e957.

引证文献7

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部